TRANSESOPHAGEAL LOW-ENERGY SYNCHRONOUS CARDIOVERSION OF ATRIAL-FLUTTER FIBRILLATION IN THE DOG

被引:13
作者
YAMANOUCHI, Y
KUMAGAI, K
TASHIRO, N
HIROKI, T
ARAKAWA, K
机构
[1] Department of Internal Medicine, School of Medicine, Fukuoka University, Fukuoka
关键词
D O I
10.1016/0002-8703(92)90655-F
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to determine the feasibility and efficacy of terminating atrial flutter/fibrillation using low-energy synchronous shocks delivered through a transesophageal catheter in dogs with talc-induced pericarditis. Atrial flutter/fibrillation was induced by employing the pulse train method. The minimum effective cardioversion energy level was compared for three different methods-method A, delivery between a distal esophageal electrode and a proximal esophageal electrode; method B, delivery of shocks through a distal esophageal electrode and a plate placed on the chest; method C, transthoracic cardioversion. The minimum effective cardioversion energy level did not differ significantly between methods A and B 1.30 +/- 0.46 joules versus 1.29 +/- 0.35 joules). Transesophageal cardioversion decreased the defibrillation threshold three- to fourfold from that of conventional transthoracic cardioversion. There were no complications of heart block, ventricular fibrillation, or any pathologic evidence of esophageal injury. Thus transesophageal low-energy synchronous cardioversion is considered a feasible and effective method for the treatment of atrial flutter/fibrillation.
引用
收藏
页码:417 / 420
页数:4
相关论文
共 18 条
[1]  
BENDITT DG, 1984, MED CLIN N AM, V68, P865
[2]   TRANS-ESOPHAGEAL STUDY OF INFANT SUPRA-VENTRICULAR TACHYCARDIA - ELECTROPHYSIOLOGIC CHARACTERISTICS [J].
BENSON, DW ;
DUNNIGAN, A ;
BENDITT, DG ;
PRITZKER, MR ;
THOMPSON, TR .
AMERICAN JOURNAL OF CARDIOLOGY, 1983, 52 (08) :1002-1006
[3]  
BUCKNALL CA, 1987, BRIT HEART J, V58, P245
[4]   MYOCARDIAL NECROSIS FROM DIRECT-CURRENT COUNTERSHOCK - EFFECT OF PADDLE ELECTRODE SIZE AND TIME INTERVAL BETWEEN DISCHARGES [J].
DAHL, CF ;
EWY, GA ;
WARNER, ED ;
THOMAS, ED .
CIRCULATION, 1974, 50 (05) :956-961
[5]   CLINICAL-EXPERIENCE, COMPLICATIONS, AND SURVIVAL IN 70 PATIENTS WITH THE AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR [J].
ECHT, DS ;
ARMSTRONG, K ;
SCHMIDT, P ;
OYER, PE ;
STINSON, EB ;
WINKLE, RA .
CIRCULATION, 1985, 71 (02) :289-296
[6]   EFFECTS OF ELECTRICAL COUNTERSHOCK ON SERUM CREATINE-PHOSPHOKINASE (CPK) ISOENZYME ACTIVITY [J].
EHSANI, A ;
EWY, GA ;
SOBEL, BE .
AMERICAN JOURNAL OF CARDIOLOGY, 1976, 37 (01) :12-18
[7]  
FRITHZ G, 1970, ACTA MED SCAND, V187, P271
[8]   ESOPHAGEAL PACING - A DIAGNOSTIC AND THERAPEUTIC TOOL [J].
GALLAGHER, JJ ;
SMITH, WM ;
KERR, CR ;
COOK, JKL ;
REITER, M ;
STERBA, R ;
HARTE, M .
CIRCULATION, 1982, 65 (02) :336-341
[9]  
GRITELLI G, 1983, AM J CARDIOL, V51, P513
[10]   LOW-ENERGY SYNCHRONOUS CARDIOVERSION OF VENTRICULAR-TACHYCARDIA USING A CATHETER ELECTRODE IN A CANINE MODEL OF SUB-ACUTE MYOCARDIAL-INFARCTION [J].
JACKMAN, WM ;
ZIPES, DP .
CIRCULATION, 1982, 66 (01) :187-195