QUANTITATION OF CD62, SOLUBLE CD62, AND LYSOSOME-ASSOCIATED MEMBRANE-PROTEIN-1 AND MEMBRANE-PROTEIN-2 FOR EVALUATION OF THE QUALITY OF STORED PLATELET CONCENTRATES

被引:48
作者
DIVERS, SG
KANNAN, K
STEWART, RM
BETZING, KW
DEMPSEY, D
FUKUDA, M
CHERVENAK, R
HOLCOMBE, RF
机构
[1] LOUISIANA STATE UNIV,MED CTR,DEPT MED,SHREVEPORT,LA 71130
[2] LOUISIANA STATE UNIV,MED CTR,CTR EXCELLENCE CANC RES,SHREVEPORT,LA 71130
[3] LOUISIANA STATE UNIV,MED CTR,CTR EXCELLENCE ARTHRIT & RHEUMATOL,SHREVEPORT,LA 71130
[4] LOUISIANA STATE UNIV,MED CTR,DEPT MICROBIOL & IMMUNOL,SHREVEPORT,LA 71130
[5] LA JOLLA CANC RES FDN,LA JOLLA,CA
关键词
D O I
10.1046/j.1537-2995.1995.35495216076.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Platelets become activated during storage, which results in secretion of granules, vesiculation of microparticles, secretion of protein, and a number of other biochemical and morphologic processes that decrease the utility of platelet concentrates stored for transfusion. Study Design and Methods:To evaluate the quality of stored platelet concentrates, the cell surface expression of specific activation-dependent antigens (CD62 and lysosome-associated membrane proteins 1 and 2 [LAMP-1, LAMP-2]) on platelets stored in a hospital blood bank over a 7-day period was examined. Relative microparticle counts and the expression of CD62 by microparticles, as well as platelet concentrate supernatant levels of soluble CD62, were determined. Results: The percentage of platelets expressing CD62 increased significantly from Day 1 to Day 5 (p<0.05) of storage; the mean fluorescence Values for CD62 did not, In contrast, the mean fluorescence values of LAMP-I and LAMP-2 rose significantly (p<0.01 and p<0.05, respectively) between Days 1 and 5. Significant declines in CD62, LAMP-1, and LAMP-2 percent expression and mean fluorescence were seen on Day 6 of storage (p<0.001). Microparticle numbers increased significantly during storage and correlated with levels of CD62 protein (free and membrane-bound) (r = 0.95 vs. Day 2, p<0.05; r = 0.88 vs. Day 5, p<0.05). Conclusion: Flow cytometric evaluations of the expression of cell surface CD62, LAMP-1, and LAMP-2 are complementary tests that, especially when used in conjunction with the quantitation of CD62 protein, provide a simple and effective means of evaluating the quality of platelet concentrates stored for transfusion.
引用
收藏
页码:292 / 297
页数:6
相关论文
共 27 条
  • [1] ABRAMS CS, 1990, BLOOD, V75, P128
  • [2] BESSOS H, 1992, THROMB RES, V59, P497
  • [3] BODE AP, 1992, BLOOD CELLS, V18, P361
  • [4] BODE AP, 1991, BLOOD, V77, P887
  • [5] CARLSSON SR, 1988, J BIOL CHEM, V263, P18911
  • [6] CORASH L, 1990, BLOOD CELLS, V16, P97
  • [7] CHARACTERIZATION OF GMP-140 (P-SELECTIN) AS A CIRCULATING PLASMA-PROTEIN
    DUNLOP, LC
    SKINNER, MP
    BENDALL, LJ
    FAVALORO, EJ
    CASTALDI, PA
    GORMAN, JJ
    GAMBLE, JR
    VADAS, MA
    BERNDT, MC
    [J]. JOURNAL OF EXPERIMENTAL MEDICINE, 1992, 175 (04) : 1147 - 1150
  • [8] GEORGE JN, 1992, BLOOD CELLS, V18, P501
  • [9] GEORGE JN, 1982, BLOOD, V60, P834
  • [10] GILBERT GE, 1991, J BIOL CHEM, V266, P17261