DETERMINATION OF CYCLODEXTRINS IN SERUM BY REVERSED-PHASE CHROMATOGRAPHY WITH PULSED AMPEROMETRIC DETECTION AND A MEMBRANE REACTOR

被引:14
作者
HAGINAKA, J
NISHIMURA, Y
YASUDA, H
机构
[1] Faculty of Pharmaceutical Sciences, Mukogawa Women's University, Nishinomiya, Hyogo, 663, 11-68, Koshien Kyuban-cho
关键词
CYCLODEXTRIN DETERMINATION; PULSED AMPEROMETRIC DETECTION; REVERSED-PHASE CHROMATOGRAPHY; MEMBRANE REACTOR;
D O I
10.1016/0731-7085(93)80064-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high-performance liquid chromatographic method has been developed for the determination of cyclodextrins (CDs) in serum. The method involves solid-phase extraction of CDs, separation on a C18 reversed-phase column using a mixture of water, tetrahydrofuran and methanol as an eluent, eluent pH modification with a cation-exchange membrane reactor surrounded by 1.5 M sodium hydroxide solutions, and pulsed amperometric detection (PAD) with a gold working electrode. The solid-phase extraction on a C18 bonded-silica column was effective for removing the PAD sensitive components in serum. The calibration graphs constructed by internal standard method were linear over the range 6.25-200 pmol of CDs in serum. The detection limits for CDs were about 5 pmol at a signal-to-noise ratio of 3.
引用
收藏
页码:1023 / 1026
页数:4
相关论文
共 13 条
[1]   NEW METHODS FOR RAPID SEPARATION AND DETECTION OF OLIGOSACCHARIDES FROM GLYCOPROTEINS [J].
CHEN, LM ;
YET, MG ;
SHAO, MC .
FASEB JOURNAL, 1988, 2 (12) :2819-2824
[2]  
HAGINAKA J, 1988, J CHROMATOGR, V447, P268, DOI 10.1016/0021-9673(88)90034-9
[3]   DETERMINATION OF CYCLODEXTRINS AND BRANCHED CYCLODEXTRINS BY REVERSED-PHASE CHROMATOGRAPHY WITH PULSED AMPEROMETRIC DETECTION AND A MEMBRANE REACTOR [J].
HAGINAKA, J ;
NISHIMURA, Y ;
WAKAI, J ;
YASUDA, H ;
KOIZUMI, K ;
NOMURA, T .
ANALYTICAL BIOCHEMISTRY, 1989, 179 (02) :336-340
[4]   MONOSACCHARIDE ANALYSIS OF GLYCOCONJUGATES BY ANION-EXCHANGE CHROMATOGRAPHY WITH PULSED AMPEROMETRIC DETECTION [J].
HARDY, MR ;
TOWNSEND, RR ;
LEE, YC .
ANALYTICAL BIOCHEMISTRY, 1988, 170 (01) :54-62
[5]   SEPARATION OF POSITIONAL ISOMERS OF OLIGOSACCHARIDES AND GLYCOPEPTIDES BY HIGH-PERFORMANCE ANION-EXCHANGE CHROMATOGRAPHY WITH PULSED AMPEROMETRIC DETECTION [J].
HARDY, MR ;
TOWNSEND, RR .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1988, 85 (10) :3289-3293
[6]  
KOIZUMI K, 1989, J CHROMATOGR, V464, P365
[7]   DETERMINATION OF CYCLIC GLUCANS BY ANION-EXCHANGE CHROMATOGRAPHY WITH PULSED AMPEROMETRIC DETECTION [J].
KOIZUMI, K ;
KUBOTA, Y ;
TANIMOTO, T ;
OKADA, Y .
JOURNAL OF CHROMATOGRAPHY, 1988, 454 :303-310
[8]   QUANTITATION OF CHROMATOGRAPHICALLY SEPARATED MALTOOLIGOSACCHARIDES WITH A SINGLE CALIBRATION CURVE USING A POSTCOLUMN ENZYME REACTOR AND PULSED AMPEROMETRIC DETECTION [J].
LAREW, LA ;
JOHNSON, DC .
ANALYTICAL CHEMISTRY, 1988, 60 (18) :1867-1872
[9]  
Ohsawa K., 1986, ANAL SCI, V2, P165
[10]   DETERMINATION OF CARBOHYDRATES BY ANION-EXCHANGE CHROMATOGRAPHY WITH PULSED AMPEROMETRIC DETECTION [J].
ROCKLIN, RD ;
POHL, CA .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1983, 6 (09) :1577-1590