PHOSPHORIMETRIC DETECTION IN HPLC VIA TRIVALENT LANTHANIDES - HIGH-SENSITIVITY TIME-RESOLVED LUMINESCENCE DETECTION OF TETRACYCLINES USING EU3+ IN A MICELLAR POST COLUMN REAGENT

被引:32
作者
DUGGAN, JX
机构
[1] Perkin-Elmer Corporation, Oak Brook, Illinois, 60522
来源
JOURNAL OF LIQUID CHROMATOGRAPHY | 1991年 / 14卷 / 13期
关键词
D O I
10.1080/01483919108049335
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The detection of tetracyclines in HPLC by sensitized Europium phosphorescence has been reinvestigated using a dedicated LC detector with time-resolved luminescence capability. A micellar Eu3+ post column reagent was developed which contained 1% Triton X-100 and 200uM tri-n-octyl phosphine oxide buffered at pH 10.5. This reagent provided optimized time-resolved detection and was found to be compatible with a several mobile phases used in reversed phase chromatography of tetracyclines. The sensitivity and quantitative linearity of the technique was determined using standard fluorometric and time-resolved modes of detection with both grating and filter emission monochromation. Peak areas were linear with concentration from 2 ug on column to the limit of detection. Subnanogram limits of detection were obtained for both tetracycline and oxytetracycline. The relative sensitivity of the technique for compounds tested was oxytetracycline = tetracycline > doxycycline > chlortetracycline > > minocycline. The high selectivity of this method promises to be useful in simplifying chromatograms from complex matrices such as physiological fluids and may also provide positive evidence for the presence of tetracyclines or structural analogs in a number of sample types.
引用
收藏
页码:2499 / 2525
页数:27
相关论文
共 18 条
  • [1] ASZALOS A, 1982, ANAL TETRACYCLINE AN, V5, P367
  • [2] LANTHANIDE IONS AS LUMINESCENT CHROMOPHORES FOR LIQUID-CHROMATOGRAPHIC DETECTION
    DIBELLA, EE
    WEISSMAN, JB
    JOSEPH, MJ
    SCHULTZ, JR
    WENZEL, TJ
    [J]. JOURNAL OF CHROMATOGRAPHY, 1985, 328 (JUN): : 101 - 109
  • [3] GEORGES J, 1990, SPECTROCHIM ACTA REV, V13, P41
  • [4] HAERTLE T, 1981, NUCLEIC ACIDS RES, V9, P6194
  • [5] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATIONS OF TETRACYCLINE DERIVATIVES USING VOLATILE MOBILE PHASES
    HASAN, T
    COOPERMAN, BS
    [J]. JOURNAL OF CHROMATOGRAPHY, 1985, 321 (02): : 462 - 466
  • [6] EUROPIUM AS A LABEL IN TIME-RESOLVED IMMUNOFLUOROMETRIC ASSAYS
    HEMMILA, I
    DAKUBU, S
    MUKKALA, VM
    SIITARI, H
    LOVGREN, T
    [J]. ANALYTICAL BIOCHEMISTRY, 1984, 137 (02) : 335 - 343
  • [7] LANTHANIDE-SENSITIZED LUMINESCENCE FOR THE DETECTION OF TETRACYCLINES
    HIRSCHY, LM
    DOSE, EV
    WINEFORDNER, JD
    [J]. ANALYTICA CHIMICA ACTA, 1983, 147 (MAR) : 311 - 316
  • [8] HIRSHY L, 1983, THESIS U FLORIDA GAI
  • [9] KNOX JH, 1979, J CHROMATOGR, V186, P763, DOI 10.1016/S0021-9673(00)95294-4
  • [10] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SYSTEM FOR ANALYSIS OF TETRACYCLINE DRUG STANDARDS, ANALOGS, DEGRADATION PRODUCTS AND OTHER IMPURITIES
    MACK, GD
    ASHWORTH, RB
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1978, 16 (03) : 93 - 101