INERT-GAS SECONDARY ENCLOSURE CLEANUP SYSTEM

被引:18
作者
SHMAYDA, WT
KHERANI, NP
WALLACE, B
MAZZA, F
机构
[1] CANADIAN FUS FUELS TECHNOL PROJECT,MISSISSAUGA L5J 1K3,ONTARIO,CANADA
[2] SAES GETTERS SPA,I-20151 MILAN,ITALY
来源
FUSION TECHNOLOGY | 1992年 / 21卷 / 02期
关键词
D O I
10.13182/FST92-A29816
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
St 198 alloy is attractive for glovebox clean-up systems operating with nitrogen cover gases, offering good tolerance to impurities which may permeate into the box from the environment and stable sorption speeds for alloy loadings as high as 360 mCi/g. At this loading the tritium concentration in the stream leaving the scavenger bed will be of the order of 400-mu-Ci/m3. The alloy operating conditions can be adjusted to increase the quantity of tritium stored in the alloy or to reduce the tritium concentration in the effluent. Methane can not be removed from a nitrogen stream with St 198. A glovebox clean-up system based on the use of this alloy is under evaluation.
引用
收藏
页码:616 / 621
页数:6
相关论文
共 5 条
[1]  
GILDEA PD, 1978, 3RD P TOP M TECHN CO, P745
[2]  
KERSHNER CJ, 1974, P S TRITIUM TECHNOLO, V50, P50
[3]   FEASIBILITY OF CHEMICAL GETTER BEDS IN SCAVENGING TRITIUM FROM INERT-GASES [J].
MAIENSCHEIN, JL .
NUCLEAR TECHNOLOGY, 1978, 38 (03) :387-404
[4]  
MILLER HH, 1980, P TRITIUM TECHNOLOGY, P208
[5]   RESIDUAL TRITIATED-WATER IN MOLECULAR-SIEVES [J].
NASISE, JE ;
CARLSON, RV ;
JALBERT, RA .
FUSION TECHNOLOGY, 1986, 10 (03) :1334-1339