IMAGE-ANALYSIS CONFIRMATION OF DNA ANEUPLOIDY IN FLOW CYTOMETRIC DNA DISTRIBUTIONS HAVING A WIDE COEFFICIENT OF VARIATION OF THE G0/G1 PEAK

被引:54
作者
MCFADDEN, PW [1 ]
CLOWRY, LJ [1 ]
DAEHNERT, K [1 ]
HAUSE, LL [1 ]
KOETHE, SM [1 ]
机构
[1] MED COLL WISCONSIN,DEPT PATHOL,MILWAUKEE,WI 53226
关键词
DNA content; flow cytometry; image analysis;
D O I
10.1093/ajcp/93.5.637
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
With nuclei extracted from paraffin-embedded tissues, resolution of normal diploid DNA and abnormal near-diploid/aneuploid populations by flow cytometry (FCM) is especially difficult. These samples, compared with fresh tissue, tend to show a broader DNA distribution, appearing as a wide (high) coefficient of variation (CV) of the G0/G1 peak. To address the question of whether there may be aneuploid populations hidden in wide CV diploid G0/G1 peaks, the authors measured DNA content in nuclei extracted from paraffin-embedded tumor tissue by morphometric image analysis (LA) in addition to FCM. Of 29 samples showing little evidence of DNA aneuploidy by FCM, in 20 of 20 with G0/G1 CVs greater than or equal to 5.50% there was an aneuploid population when analysis was performed by IA. Of the remaining nine samples with CVs less than or equal to 4.41%, all were diploid in the G0/G1 region by both FCM and IA. The presence of aneuploid populations in FCM distributions with wide CV G0/G1 peaks can be confirmed by IA.
引用
收藏
页码:637 / 642
页数:6
相关论文
共 10 条
[1]   OPTICAL MICROSCOPE SYSTEM FOR STANDARDIZED CELL MEASUREMENTS AND ANALYSES [J].
BACUS, JW ;
GRACE, LJ .
APPLIED OPTICS, 1987, 26 (16) :3280-3293
[2]  
BAUER KD, 1986, CANCER RES, V46, P2428
[3]   METHOD FOR QUANTITATIVE-EVALUATION OF DATA FROM FLOW MICROFLUOROMETRY [J].
FRIED, J .
COMPUTERS AND BIOMEDICAL RESEARCH, 1976, 9 (03) :263-276
[4]   APPLICATION OF DNA FLOW-CYTOMETRY TO PARAFFIN-EMBEDDED ARCHIVAL MATERIAL FOR THE STUDY OF ANEUPLOIDY AND ITS CLINICAL-SIGNIFICANCE [J].
HEDLEY, DW ;
FRIEDLANDER, ML ;
TAYLOR, IW .
CYTOMETRY, 1985, 6 (04) :327-333
[5]   METHOD FOR ANALYSIS OF CELLULAR DNA CONTENT OF PARAFFIN-EMBEDDED PATHOLOGICAL MATERIAL USING FLOW-CYTOMETRY [J].
HEDLEY, DW ;
FRIEDLANDER, ML ;
TAYLOR, IW ;
RUGG, CA ;
MUSGROVE, EA .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1983, 31 (11) :1333-1335
[6]  
HEDLEY DW, 1984, CANCER RES, V44, P5395
[7]  
LOOK AT, 1985, BLOOD, V65, P1079
[8]   THE USE OF FLOW-CYTOMETRY IN THE DIAGNOSIS AND BIOLOGICAL CHARACTERIZATION OF THE NON-HODGKINS-LYMPHOMAS [J].
SHACKNEY, SE .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1986, 468 :171-177
[9]  
SHAPIRO HM, 1988, PRACTICAL FLOW CYTOM, P84
[10]   TECHNICAL AND STATISTICAL IMPROVEMENTS FOR FLOW CYTOMETRIC DNA ANALYSIS OF PARAFFIN-EMBEDDED TISSUE [J].
SICKLESANTANELLO, BJ ;
FARRAR, WB ;
DECENZO, JF ;
KEYHANIROFAGHA, S ;
KLEIN, J ;
PEARL, D ;
LAUFMAN, H ;
OTOOLE, RV .
CYTOMETRY, 1988, 9 (06) :594-599