CAROTID-ARTERY OCCLUSION - POSITIVE PREDICTIVE VALUE OF DUPLEX SONOGRAPHY COMPARED WITH ARTERIOGRAPHY

被引:37
作者
KIRSCH, JD
WAGNER, LR
JAMES, EM
CHARBONEAU, JW
NICHOLS, DA
MEYER, FB
HALLETT, JW
机构
[1] MAYO CLIN & MAYO FDN,DEPT DIAGNOST RADIOL,ROCHESTER,MN 55905
[2] MAYO CLIN & MAYO FDN,DEPT NEUROL SURG,ROCHESTER,MN
[3] MAYO CLIN & MAYO FDN,DIV VASC SURG,ROCHESTER,MN
关键词
D O I
10.1016/S0741-5214(94)70037-0
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: Duplex ultrasonography is an accurate, noninvasive method for diagnosing, characterizing and classifying atherosclerotic stenoses of the extracranial carotid artery system. To date, however, no large series has studied the predictive value of duplex sonography in the diagnosis of carotid artery occlusion, an important consideration, given the marked difference in clinical treatment between patients with high-grade stenosis (surgical therapy) and those with occlusive disease (nonsurgical therapy). Methods: We retrospectively reviewed 158 patients with 174 occluded carotid artery segments (examined over a 61/2-pear period) to determine the predictive value of duplex sonography in differentiating carotid artery occlusion from high-grade stenosis. Results: All patients had arteriographic correlation. Duplex ultrasonography had a positive predictive value of 92.5% (7.5% false-positive rate; 95% confidence interval, 3.6% to 11.4%) in establishing a diagnosis of carotid artery occlusion. Further analysis revealed no significant improvement in the false-positive rate with the addition of color Doppler how imaging to high-resolution B-mode scanning and pulsed Doppler spectral analysis. Predictive value increased to 96.7% (95% confidence interval, 90.7% to 99.3%) over the last 2 years of the study, a statistically significant improvement. Conclusions: We believe that duplex ultrasonography is an acceptably accurate method for diagnosing carotid arterial occlusion in most patients. Arteriography should be reserved for patients with symptoms who are surgical candidates to identify those who may still have a surgically correctable high-grade stenosis.
引用
收藏
页码:642 / 649
页数:8
相关论文
共 16 条
[1]   THE LIMITATIONS OF DIAGNOSIS OF CAROTID OCCLUSION BY DOPPLER ULTRASOUND [J].
BORNSTEIN, NM ;
BELOEV, ZG ;
NORRIS, JW .
ANNALS OF SURGERY, 1988, 207 (03) :315-317
[2]   CLINICAL CORRELATES OF DOPPLER ULTRASOUND ERRORS IN THE DETECTION OF INTERNAL CAROTID-ARTERY OCCLUSION [J].
BRIDGERS, SL .
STROKE, 1989, 20 (05) :612-615
[3]   CAROTID SURGERY WITHOUT ANGIOGRAPHY [J].
CREW, JR ;
DEAN, M ;
JOHNSON, JM ;
KNIGHTON, D ;
BASHOUR, TT ;
ELLERTSON, D ;
HANNA, ES .
AMERICAN JOURNAL OF SURGERY, 1984, 148 (02) :217-220
[4]   STENOSIS OF THE INTERNAL CAROTID-ARTERY - ASSESSMENT USING COLOR DOPPLER IMAGING COMPARED WITH ANGIOGRAPHY [J].
ERICKSON, SJ ;
MEWISSEN, MW ;
FOLEY, WD ;
LAWSON, TL ;
MIDDLETON, WD ;
QUIROZ, FA ;
MACRANDER, SJ ;
LIPCHIK, EO .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (06) :1299-1305
[5]  
HAYNES B, 1992, CAN J SURG, V35, P446
[6]   DUPLEX CAROTID SONOGRAPHY - CRITERIA FOR STENOSIS, ACCURACY, AND PITFALLS [J].
JACOBS, NM ;
GRANT, EG ;
SCHELLINGER, D ;
BYRD, MC ;
RICHARDSON, JD ;
COHAN, SL .
RADIOLOGY, 1985, 154 (02) :385-391
[7]   COLOR-FLOW DOPPLER IMAGING OF CAROTID-ARTERY ABNORMALITIES [J].
MIDDLETON, WD ;
FOLEY, WD ;
LAWSON, TL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (02) :419-425
[8]  
OLEARY DH, 1983, AM J NEURORADIOL, V4, P759
[9]  
PEXMAN JHW, 1987, AM J NEURORADIOL, V8, P485
[10]   INTERNAL CAROTID-ARTERY STENOSIS - ACCURACY AND REPRODUCIBILITY OF COLOR-DOPPLER-ASSISTED DUPLEX IMAGING [J].
POLAK, JF ;
DOBKIN, GR ;
OLEARY, DH ;
WANG, AM ;
CUTLER, SS .
RADIOLOGY, 1989, 173 (03) :793-798