ENDOTRACHEAL-TUBE CUFF PRESSURE ASSESSMENT - PITFALLS OF FINGER ESTIMATION AND NEED FOR OBJECTIVE MEASUREMENT

被引:78
作者
FERNANDEZ, R [1 ]
BLANCH, L [1 ]
MANCEBO, J [1 ]
BONSOMS, N [1 ]
ARTIGAS, A [1 ]
机构
[1] UNIV AUTONOMA BARCELONA,FAC MED,DEPT FISIOL,SABADELL,SPAIN
关键词
D O I
10.1097/00003246-199012000-00023
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Estimation of endotracheal (ET) cuff pressure by finger palpation is one of the methods currently used in the clinical setting. We compared the accuracy of this method with instrumental intracuff pressure measurement in tracheal model tests by 20 members of our ICU team. Four different ET tubes at three different pressure levels were examined. Accuracy for the estimated method by finger palpation was 69% for high pressures, 58% for normal pressures, and 73% for low pressures. We observed differences in terms of sensitivity, specificity, and positive predictive power between different tubes reflecting differences in tube characteristics and interobserver variability. We conclude that precise intracuff pressure measurement is mandatory to prevent complications of over- or underinflation.
引用
收藏
页码:1423 / 1426
页数:4
相关论文
共 13 条
[1]   CHANGES IN TRACHEAL CUFF PRESSURE DURING RESPIRATORY SUPPORT [J].
BADENHORST, CH .
CRITICAL CARE MEDICINE, 1987, 15 (04) :300-302
[2]   PROLONGED ENDOTRACHEAL INTUBATION VS TRACHEOSTOMY [J].
BERLAUK, JF .
CRITICAL CARE MEDICINE, 1986, 14 (08) :742-745
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   REAPPRAISAL OF TRACHEAL INJURY FROM CUFFED TRACHEOSTOMY TUBES - EXPERIMENTS IN DOGS [J].
BRYANT, LR ;
TRINKLE, JK ;
DUBILIER, L .
JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1971, 215 (04) :625-&
[5]   CHANGE IN TRACHEAL BLOOD-FLOW DURING ENDOTRACHEAL INTUBATION [J].
JOH, S ;
MATSUURA, H ;
KOTANI, Y ;
SUGIYAMA, K ;
HIROTA, Y ;
KIYOMITSU, Y ;
KUBOTA, Y .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1987, 31 (04) :300-304
[6]   CONTROL OF ENDOTRACHEAL-TUBE CUFF PRESSURE USING A SIMPLE DEVICE [J].
KAY, J ;
FISHER, JA .
ANESTHESIOLOGY, 1987, 66 (02) :253-253
[7]  
LAWRENCE JC, 1986, ANAESTH INTENS CARE, V14, P466
[8]   PREVENTION OF COMPLICATIONS FROM PROLONGED TRACHEAL INTUBATION [J].
LEWIS, FR ;
SCHLOBOHM, RM ;
THOMAS, AN .
AMERICAN JOURNAL OF SURGERY, 1978, 135 (03) :452-457
[9]  
MAGOVERN GJ, 1972, J THORAC CARDIOV SUR, V64, P747
[10]   WORK PRACTICES RELATING TO INTUBATION AND ASSOCIATED PROCEDURES IN INTENSIVE-CARE UNITS IN SWEDEN [J].
MEHTA, S ;
MICKIEWICZ, M .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1986, 30 (08) :637-641