INFLUENCE OF LEFT-VENTRICULAR FUNCTION ON SURVIVAL AND MODE OF DEATH AFTER IMPLANTABLE DEFIBRILLATOR THERAPY (CLEVELAND CLINIC FOUNDATION AND MONTEFIORE MEDICAL-CENTER EXPERIENCE)

被引:36
作者
KIM, SG
MALONEY, JD
PINSKI, SL
CHOUE, CW
FERRICK, KJ
ROTH, JA
GROSS, J
BRODMAN, R
FURMAN, S
FISHER, JD
机构
[1] MONTEFIORE MED CTR,DEPT CARDIOTHORAC SURG,BRONX,NY 10467
[2] CLEVELAND CLIN EDUC FDN,DIV CARDIOL,CLEVELAND,OH 44106
关键词
D O I
10.1016/0002-9149(93)90294-M
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To determine the influence of left ventricular (LV) function on survival and mode of death in patients with an implantable cardioverter-defibrillator (ICD), sudden death, surgical mortality, total arrhythmia-related death, total cardiac death and total death were retrospectively evaluated in 377 consecutive patients. The outcomes were also compared between patients with an LV ejection fraction greater-than-or-equal-to 30% (214 patients, group 1) and <30% (148 patients, group 2). Surgical mortality was 3.9% (1.8% in group 1, 7% in group 2). During the follow-up of 25 +/- 20 months, actuarial survival rates of all patients at 3 years were 96% for sudden deaths, 81% for total cardiac deaths and 74% for total mortality. When the 2 groups were compared, survival rates of groups 1 and 2 at 3 years, respectively, were 99 and 90% for sudden death (p < 0.05), 97 and 84% for sudden death and surgical mortality (p < 0.01), 94 and 80% for the total arrhythmia-related death (p < 0.001), 88 and 68% for total cardiac death (p < 0.0001), and 81 and 62% for total mortality (p < 0.002). In group 2, 73% of total cardiac deaths within 1 year were causally related to the arrhythmia. Thus, in patients with an ICD, sudden death rates were very low. However, total cardiac death and total death rates were relatively higher. The outcomes of patients with an ICD were strongly influenced by the degree of LV dysfunction. In group 2 patients, although the sudden death rate was relatively low (10% at 3 years), surgical mortality rate, total cardiac death rate and total mortality rate were substantial. A significant majority of total cardiac deaths were causally related to the arrhythmia.
引用
收藏
页码:1263 / 1267
页数:5
相关论文
共 26 条
[1]  
AKHTAR M, 1992, CIRCULATION S1, V85, P139
[2]  
[Anonymous], 1991, AM J CARDIOL, V67, P578
[3]   EFFICACY OF THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR IN PROLONGING SURVIVAL IN PATIENTS WITH SEVERE UNDERLYING CARDIAC DISEASE [J].
FOGOROS, RN ;
ELSON, JJ ;
BONNET, CA ;
FIEDLER, SB ;
BURKHOLDER, JA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (02) :381-386
[4]   AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - PATIENT SURVIVAL, BATTERY LONGEVITY AND SHOCK DELIVERY ANALYSIS [J].
GABRY, MD ;
BRODMAN, R ;
JOHNSTON, D ;
FRAME, R ;
KIM, SG ;
WASPE, LE ;
FISHER, JD ;
FURMAN, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (06) :1349-1356
[5]   WHEN SUDDEN CARDIAC DEATH IS NOT SO SUDDEN - LESSONS LEARNED FROM THE AUTOMATIC IMPLANTABLE DEFIBRILLATOR [J].
GUARNIERI, T ;
LEVINE, JH ;
GRIFFITH, LSC ;
VELTRI, EP .
AMERICAN HEART JOURNAL, 1988, 115 (01) :205-207
[6]   ARE THE BENEFITS OF THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR (AICD) OVERESTIMATED BY SUDDEN-DEATH RATE [J].
HENTHORN, RW ;
WALLER, TJ ;
HIRATZKA, LF .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (07) :1593-1594
[7]   LONG-TERM RESULTS OF AMIODARONE THERAPY IN PATIENTS WITH RECURRENT SUSTAINED VENTRICULAR-TACHYCARDIA OR VENTRICULAR-FIBRILLATION [J].
HERRE, JM ;
SAUVE, MJ ;
MALONE, P ;
GRIFFIN, JC ;
HELMY, I ;
LANGBERG, JJ ;
GOLDBERG, H ;
SCHEINMAN, MM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (02) :442-449
[8]  
Kim S G, 1991, J Interv Cardiol, V4, P241, DOI 10.1111/j.1540-8183.1991.tb00801.x
[9]   MANAGEMENT OF SURVIVORS OF CARDIAC-ARREST - IS ELECTROPHYSIOLOGIC TESTING OBSOLETE IN THE ERA OF IMPLANTABLE DEFIBRILLATORS [J].
KIM, SG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (03) :756-762
[10]   INFLUENCE OF LEFT-VENTRICULAR FUNCTION ON OUTCOME OF PATIENTS TREATED WITH IMPLANTABLE DEFIBRILLATORS [J].
KIM, SG ;
FISHER, JD ;
CHOUE, CW ;
GROSS, J ;
ROTH, J ;
FERRICK, KJ ;
BRODMAN, R ;
FURMAN, S .
CIRCULATION, 1992, 85 (04) :1304-1310