PHASE-SCRAMBLED RF EXCITATION FOR 3D VOLUME-SELECTIVE MULTISLICE NMR IMAGING

被引:10
作者
OH, CH [1 ]
HILAL, SK [1 ]
WU, EX [1 ]
CHO, ZH [1 ]
机构
[1] COLUMBIA UNIV,DEPT RADIOL,NEW YORK,NY 10027
关键词
D O I
10.1002/mrm.1910280210
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An RF excitation technique with which one can improve the effective dynamic range of the receiver and reduce the interference between slices for 3D volume‐selective multislice MRI is described. The basic idea of the technique is to use phase scrambling in conjunction with slice encoding through the use of RF pulses. The spins in each slice are encoded by RF pulses which have the scrambled as well as slice‐encoded phase components along the slice‐selection direction. The scrambled, or randomly distributed, phase reduces the peak signal intensity, thereby reducing the dynamic range of the signal. Since the proposed technique utilizes RF slice encoding together with phase scrambling, interslice image interference is greatly reduced and the dynamic range is improved. In addition, the method has several advantages such as a reduction in the power requirement for the RF pulses and the elimination of the necessity for hardware such as nonlinear gradient coils.© 1992 Academic Press,Inc. Copyright © 1992 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:290 / 299
页数:10
相关论文
共 16 条
[1]   FOURIER-TRANSFORM NUCLEAR MAGNETIC-RESONANCE TOMOGRAPHIC IMAGING [J].
CHO, ZH ;
KIM, HS ;
SONG, HB ;
CUMMING, J .
PROCEEDINGS OF THE IEEE, 1982, 70 (10) :1152-1173
[2]   PHASE-OFFSET MULTIPLANAR (POMP) VOLUME IMAGING - A NEW TECHNIQUE [J].
GLOVER, GH .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (04) :457-461
[3]   TRANSVERSE HADAMARD SPECTROSCOPIC IMAGING TECHNIQUE [J].
GOELMAN, G ;
SUBRAMANIAN, VH ;
LEIGH, JS .
JOURNAL OF MAGNETIC RESONANCE, 1990, 89 (03) :437-454
[4]   B1-INSENSITIVE HADAMARD SPECTROSCOPIC IMAGING TECHNIQUE [J].
GOELMAN, G ;
LEIGH, JS .
JOURNAL OF MAGNETIC RESONANCE, 1991, 91 (01) :93-101
[5]   CHEMICAL-SHIFT IMAGING WITH PHASE-ENCODING RF PULSES [J].
HENNIG, J .
MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (02) :289-298
[6]  
HENNIG J, 1991, 10TH P ANN M SOC MAG, P183
[7]   DYNAMIC-RANGE IMPROVEMENT IN NMR IMAGING USING PHASE SCRAMBLING [J].
MAUDSLEY, AA .
JOURNAL OF MAGNETIC RESONANCE, 1988, 76 (02) :287-305
[8]  
Oh C H, 1984, IEEE Trans Med Imaging, V3, P170, DOI 10.1109/TMI.1984.4307677
[9]   A NEW PHASE CODING METHOD USING A SLICE SELECTION GRADIENT FOR HIGH-SPEED FLOW VELOCITY-MEASUREMENT IN NMR TOMOGRAPHY [J].
OH, CH ;
CHO, ZH .
PHYSICS IN MEDICINE AND BIOLOGY, 1986, 31 (11) :1237-1246
[10]  
OH CH, 1992, 11TH P ANN M SOC MAG, P3837