TOTAL NUMBER OF PARTICLES IN A BOUNDED REGION ESTIMATED DIRECTLY WITH THE NUCLEATOR - GRANULOSA-CELL NUMBER IN OVARIAN FOLLICLES

被引:13
作者
BAGGER, PV [1 ]
BANG, L [1 ]
CHRISTIANSEN, MD [1 ]
GUNDERSEN, HJG [1 ]
MORTENSEN, L [1 ]
机构
[1] AARHUS UNIV,STEREOL RES LAB,DK-8000 AARHUS,DENMARK
关键词
FRACTIONATOR; FOLLICLE; GRANULOSA CELL NUMBER; NUCLEATOR; STEREOLOGY;
D O I
10.1016/0002-9378(93)90523-L
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVE: Our objective was to evaluate the precision of the ''nucleator'' with regard to estimation of the number of granulosa cells in individual follicles and the average number of granulosa cells per follicle in a group of follicles. STUDY DESIGN: Nine murine ovarian follicles embedded in plastic were oriented isotropically with the ''orientator'' by Mattfeldt, cut into 20 mum serial sections, and stained with hematoxylin. In each follicle the number of granulosa cells was estimated in two ways, both unbiased: (1) with the nucleator principle in the section that contains the nucleolus of the oocyte and (2) in the complete set of follicle sections with the ''fractionator'' principle. Estimates with the fractionator were interpreted as ''true'' values. Therefore the precision (CE) of the nucleator estimates could be calculated. RESULTS AND CONCLUSION: The nucleator provides precise estimates of the number of granulosa cells in one complete follicle: CE = 0.12. The amount of effort is minimal, because estimation is based on roughly 50 granulosa cells. The precision of the procedure with regard to estimation of the average number of granulosa cells in a group of follicles depends mainly on the biologic variation (CV(biol) = 0.71).
引用
收藏
页码:724 / 731
页数:8
相关论文
共 12 条
[1]  
BAGGER PV, 1987, J REPROD FERTIL, V80, P251, DOI 10.1530/jrf.0.0800251
[2]  
BAGGER PV, 1989, ACTA STEREOL, V8, P123
[3]  
BAGGER PV, 1988, SERONO S REV, V14, P193
[4]   INDUCTION OF MOUSE OOCYTE MATURATION INVIVO BY PERTURBANTS OF PURINE METABOLISM [J].
DOWNS, SM ;
EPPIG, JJ .
BIOLOGY OF REPRODUCTION, 1987, 36 (02) :431-437
[5]   SOME NEW, SIMPLE AND EFFICIENT STEREOLOGICAL METHODS AND THEIR USE IN PATHOLOGICAL RESEARCH AND DIAGNOSIS - REVIEW ARTICLE [J].
GUNDERSEN, HJG ;
BENDTSEN, TF ;
KORBO, L ;
MARCUSSEN, N ;
MOLLER, A ;
NIELSEN, K ;
NYENGAARD, JR ;
PAKKENBERG, B ;
SORENSEN, FB ;
VESTERBY, A ;
WEST, MJ .
APMIS, 1988, 96 (05) :379-394
[6]   THE NEW STEREOLOGICAL TOOLS - DISECTOR, FRACTIONATOR, NUCLEATOR AND POINT SAMPLED INTERCEPTS AND THEIR USE IN PATHOLOGICAL RESEARCH AND DIAGNOSIS [J].
GUNDERSEN, HJG ;
BAGGER, P ;
BENDTSEN, TF ;
EVANS, SM ;
KORBO, L ;
MARCUSSEN, N ;
MOLLER, A ;
NIELSEN, K ;
NYENGAARD, JR ;
PAKKENBERG, B ;
SORENSEN, FB ;
VESTERBY, A ;
WEST, MJ .
APMIS, 1988, 96 (10) :857-881
[7]   THE NUCLEATOR [J].
GUNDERSEN, HJG .
JOURNAL OF MICROSCOPY-OXFORD, 1988, 151 :3-21
[8]   STEREOLOGY OF ARBITRARY PARTICLES - A REVIEW OF UNBIASED NUMBER AND SIZE ESTIMATORS AND THE PRESENTATION OF SOME NEW ONES, IN MEMORY OF THOMPSON,WILLIAM,R. [J].
GUNDERSEN, HJG .
JOURNAL OF MICROSCOPY, 1986, 143 :3-45
[9]   ESTIMATION OF SURFACE-AREA AND LENGTH WITH THE ORIENTATOR [J].
MATTFELDT, T ;
MALL, G ;
GHAREHBAGHI, H ;
MOLLER, P .
JOURNAL OF MICROSCOPY-OXFORD, 1990, 159 :301-317
[10]   THE ISECTOR - A SIMPLE AND DIRECT METHOD FOR GENERATING ISOTROPIC, UNIFORM RANDOM SECTIONS FROM SMALL SPECIMENS [J].
NYENGAARD, JR ;
GUNDERSEN, HJG .
JOURNAL OF MICROSCOPY, 1992, 165 :427-431