ARGON BEAM COAGULATION RESCUE TO CORRECT BLEEDING DURING PELVISCOPY

被引:9
作者
GALEN, DI [1 ]
JACOBSON, A [1 ]
WECKSTEIN, LN [1 ]
机构
[1] BAY AREA FERTIL MED GRP,SAN RAMON,CA
来源
JOURNAL OF THE AMERICAN ASSOCIATION OF GYNECOLOGIC LAPAROSCOPISTS | 1994年 / 1卷 / 02期
关键词
D O I
10.1016/S1074-3804(05)80779-0
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
A new technique of unipolar laparoscopic coagulation is particularly useful for the treatment of pelvic or abdominal bleeding during laparoscopic procedures. Blood present at the coagulation site is blown clear with a stream of argon gas prior to tissue coagulation. Of particular importance is the virtual absence of smoke, and because the procedure involves a nontouch technique, eschar is not removed inadvertently. The speed of tissue coagulation is faster than that of conventional bipolar and unipolar techniques.
引用
收藏
页码:146 / 149
页数:4
相关论文
共 17 条
[1]   PRESENCE OF HUMAN-IMMUNODEFICIENCY-VIRUS DNA IN LASER SMOKE [J].
BAGGISH, MS ;
POIESZ, BJ ;
JORET, D ;
WILLIAMSON, P ;
REFAI, A .
LASERS IN SURGERY AND MEDICINE, 1991, 11 (03) :197-203
[2]   ELECTROSURGICAL DEBULKING OF OVARIAN-CANCER - A NEW TECHNIQUE USING THE ARGON BEAM COAGULATOR [J].
BRAND, E ;
PEARLMAN, N .
GYNECOLOGIC ONCOLOGY, 1990, 39 (02) :115-118
[3]  
DANIELL J, 1993, J REPROD MED, V38, P121
[4]  
DANIELL JF, 1992, OBSTET GYNECOL, V80, P325
[5]  
DANIELL JF, 1992, LAPAROSCOPIC USE ARG
[6]   INVITRO PRODUCTION OF VIABLE BACTERIOPHAGE IN A LASER PLUME [J].
EDIGER, MN ;
MATCHETTE, LS .
LASERS IN SURGERY AND MEDICINE, 1989, 9 (03) :296-299
[7]  
GALEN DI, 1993, 1ST INT GYN END FILM
[8]  
GALEN DI, 1993, 22ND ANN M AM ASS GY
[9]  
GALEN DI, 1993, VIDEO J OBSTET GYNEC, V6
[10]  
GO H, 1991, J TRAUMA, V31, P1294