PHOTONEUTRONS FROM HIGH-ENERGY MEDICAL LINEAR ACCELERATORS - MEASUREMENT OF THE SPECTRUM AND DOSE USING A MINIATURE PROPORTIONAL COUNTER

被引:18
作者
KLIAUGA, P [1 ]
AMOLS, H [1 ]
机构
[1] COLUMBIA UNIV,COLL PHYS & SURG,DEPT RADIAT ONCOL,NEW YORK,NY 10032
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1995年 / 31卷 / 03期
关键词
RADIOTHERAPY; MICRODOSIMETRY; DOSIMETRY; HEALTH PHYSICS;
D O I
10.1016/0360-3016(94)00370-Z
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: A new method of measuring photoneutron dose to the patient during treatment with high energy photon or electron beams is presented. This method has the advantage of providing not only the dose, but the microdosimetric spectrum at the same time. Methods and Materials: A miniature cylindrical gas proportional counter (0.5 mm diameter by 0.5 mm height) has been used to measure scatter radiation from a 20 MV teletherapy photon beam, At atmospheric pressure, filled with propane base tissue equivalent gas, this counter simulates a unit density tissue region of approximately 0.9 mu m. We present here single event microdosimetric spectra measured outside the primary beam 1.4 m from the target. This technique allows a single measurement to determine the scattered dose due to gammas and photoneutron contamination, as well as the quality factor of the photoneutrons. Results: Spectral components from scattered photons and the photoneutrons are easily separated, and dose contributions can be estimated, The ratio of photoneutron dose measured by the proportional counter to photon dose at isocenter is 0.75 X 10(-4). Conclusions: Neutron dose was also measured using a bubble neutrometer. The proportional counter and neutrometer agree within experimental errors, This type of instrument is shown to be a viable technique for determination of exposure of patient and also personnel to photoneutrons, providing not only a dose determination, but also a spectrum that can be used to estimate quality factors for equivalent dose. Its main drawback is that it requires a lengthy (several hours) measurement because of low count rate of the neutrons.
引用
收藏
页码:629 / 633
页数:5
相关论文
共 8 条
[1]  
KELLERER A M, 1972, Current Topics in Radiation Research Quarterly, V8, P85
[2]  
KLIAUGA P, 1990, RADIAT PROT DOSIM, V31, P119
[3]   MICRODOSIMETRY AT MIDDLE-AGE - SOME OLD EXPERIMENTAL PROBLEMS AND NEW ASPIRATIONS [J].
KLIAUGA, P .
RADIATION RESEARCH, 1990, 124 (01) :S5-S15
[4]   NEUTRONS FROM HIGH-ENERGY X-RAY MEDICAL ACCELERATORS - AN ESTIMATE OF RISK TO THE RADIOTHERAPY PATIENT [J].
NATH, R ;
EPP, ER ;
LAUGHLIN, JS ;
SWANSON, WP ;
BOND, VP .
MEDICAL PHYSICS, 1984, 11 (03) :231-241
[5]  
1984, NCRP79 NAT COUNC RAD
[6]  
1972, ICRU21 INT COMM RAD
[7]  
1983, ICRU36 INT COMM RAD
[8]  
1990, ICRP PUBL, V60, P70