BIOPHYSICAL AND ANATOMICAL CONSIDERATIONS FOR SAFE AND EFFICACIOUS CATHETER ABLATION OF ARRHYTHMIAS

被引:3
作者
BARDY, GH
SAWYER, PL
机构
[1] Department of Medicine, University of Washington, Seattle, Washington
关键词
arrhythmias; catheter ablation; tachycardia;
D O I
10.1002/clc.4960130611
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The development of catheter ablation techniques for therapy of cardiac arrhythmias continues to evolve. Although many patients have benefited from catheter ablation procedures, failure to ablate the arrhythmogenic substrate and complications from the pulse used in these procedures remain too frequent occurrences. The purpose of this review is to focus on these problems of inefficacy and safety with attention directed to the role various direct current and radiofrequency pulses have had in the genesis of these difficulties. Copyright © 1990 Wiley Periodicals, Inc.
引用
收藏
页码:425 / 433
页数:9
相关论文
共 68 条
  • [1] AHSAN A J, 1990, Journal of the American College of Cardiology, V15, p20A
  • [2] RADIOFREQUENCY ABLATION OF VENTRICULAR MYOCARDIUM USING ACTIVE FIXATION AND PASSIVE CONTACT CATHETER DELIVERY SYSTEMS
    AN, H
    SAKSENA, S
    JANSSEN, M
    OSYPKA, P
    [J]. AMERICAN HEART JOURNAL, 1989, 118 (01) : 69 - 77
  • [3] EFFECT OF VOLTAGE AND CHARGE OF ELECTRICAL ABLATION PULSES ON CANINE MYOCARDIUM
    BARDY, GH
    SAWYER, PL
    JOHNSON, GW
    IVEY, TD
    REICHENBACH, DD
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 257 (05): : H1534 - H1542
  • [4] EFFECT OF DAMPED SINE-WAVE SHOCKS ON CATHETER DIELECTRIC STRENGTH
    BARDY, GH
    COLTORTI, F
    IVEY, TD
    YERKOVICH, D
    GREENE, HL
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1985, 56 (12) : 769 - 772
  • [5] CATHETER-MEDIATED ELECTRICAL ABLATION - THE RELATION BETWEEN CURRENT AND PULSE WIDTH ON VOLTAGE BREAKDOWN AND SHOCK-WAVE GENERATION
    BARDY, GH
    COLTORTI, F
    STEWART, RB
    GREENE, HL
    IVEY, TD
    [J]. CIRCULATION RESEARCH, 1988, 63 (02) : 409 - 414
  • [6] SOME FACTORS AFFECTING BUBBLE FORMATION WITH CATHETER-MEDIATED DEFIBRILLATOR PULSES
    BARDY, GH
    COLTORTI, F
    IVEY, TD
    ALFERNESS, C
    RACKSON, M
    HANSEN, K
    STEWART, R
    GREENE, HL
    [J]. CIRCULATION, 1986, 73 (03) : 525 - 538
  • [7] DEVELOPMENTS, COMPLICATIONS AND LIMITATIONS OF CATHETER-MEDIATED ELECTRICAL ABLATION OF POSTERIOR ACCESSORY ATRIOVENTRICULAR PATHWAYS
    BARDY, GH
    IVEY, TD
    COLTORTI, F
    STEWART, RB
    JOHNSON, G
    GREENE, HL
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1988, 61 (04) : 309 - 316
  • [8] BARDY GH, 1990, AM J PHYSIOL, V257, P1899
  • [9] REVERSIBLE ELECTRICAL BREAKDOWN OF LIPID BILAYER MEMBRANES - CHARGE-PULSE RELAXATION STUDY
    BENZ, R
    BECKERS, F
    ZIMMERMANN, U
    [J]. JOURNAL OF MEMBRANE BIOLOGY, 1979, 48 (02) : 181 - 204
  • [10] SUDDEN-DEATH AFTER CATHETER-INDUCED ATRIOVENTRICULAR JUNCTIONAL ABLATION
    BHARATI, S
    SCHEINMANN, MM
    MORADY, F
    HESS, DS
    LEV, M
    [J]. CHEST, 1985, 88 (06) : 883 - 889