INDIRECT PHOTOMETRIC CHROMATOGRAPHY OF ANIONS USING SODIUM NAPHTHALENETRISULFONATE

被引:27
作者
MAKI, SA [1 ]
DANIELSON, ND [1 ]
机构
[1] MIAMI UNIV,DEPT CHEM,OXFORD,OH 45056
关键词
D O I
10.1021/ac00007a010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A triply charged eluent has been characterized for anion-exchange chromatography with indirect photometric detection. Sodium naphthalenetrisulfonate has shown particular promise for the separation and detection of NO2-, Br-, No3-, SO4(2-), I-, and SCN-. The analysis of a mixture containing these anions can be performed in less than 18 min with detection limits of 0.4-1 ng for all anions. The determination of the strongly retained sulfur oxides such as dithionite, tetrathionate, and other polythionates can be easily accomplished with this highly charged eluent in a short time with high sensitivity. The chromatographic performance of this eluent requires no pH adjustment of the mobile phase. In addition, chromatograms obtained with this eluent were free from any system peaks.
引用
收藏
页码:699 / 703
页数:5
相关论文
共 24 条
  • [1] INVESTIGATIONS CONCERNING THE SYSTEM PEAK IN ION-CHROMATOGRAPHY USING INDIRECT PHOTOMETRIC DETECTION
    BRANDT, G
    VOGLER, P
    KETTRUP, A
    [J]. FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1986, 325 (03): : 252 - 254
  • [2] DORSEY JG, 1990, ANAL CHEM, V62, P324
  • [3] ANION CHROMATOGRAPHY WITH LOW-CONDUCTIVITY ELUENTS .2.
    GJERDE, DT
    SCHMUCKLER, G
    FRITZ, JS
    [J]. JOURNAL OF CHROMATOGRAPHY, 1980, 187 (01): : 35 - 45
  • [4] DETERMINATION OF INORGANIC ANIONS AT PARTS PER BILLION LEVELS USING SINGLE-COLUMN ION CHROMATOGRAPHY WITHOUT SAMPLE PRECONCENTRATION
    HECKENBERG, AL
    HADDAD, PR
    [J]. JOURNAL OF CHROMATOGRAPHY, 1984, 299 (01): : 301 - 305
  • [5] THE OCCURRENCE AND ORIGIN OF SYSTEM PEAKS IN NON-SUPPRESSED ION CHROMATOGRAPHY OF INORGANIC ANIONS WITH INDIRECT ULTRAVIOLET-ABSORPTION DETECTION
    JACKSON, PE
    HADDAD, PR
    [J]. JOURNAL OF CHROMATOGRAPHY, 1985, 346 (OCT): : 125 - 137
  • [6] KARCHMER JH, 1970, ANAL CHEM SULFUR I 1
  • [7] INDIRECT PHOTOMETRIC CHROMATOGRAPHY OF INORGANIC ANIONS USING NAPHTHOLDISULFONATE
    MAKI, SA
    DANIELSON, ND
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1990, 28 (10) : 537 - 542
  • [8] MAKI SA, IN PRESS J CHROMATOG
  • [9] DETERMINATION OF THE TETRATHIONATE CONTENT OF AN ANION-EXCHANGE RESIN
    NOVAK, G
    ERDELYI, M
    VIGVARI, M
    [J]. JOURNAL OF CHROMATOGRAPHY, 1980, 201 (NOV): : 313 - 315
  • [10] SENSITIVITY OF NON-SUPPRESSED ION CHROMATOGRAPHY USING DIVALENT ORGANIC-ACIDS AS ELUENTS
    OKADA, T
    KUWAMOTO, T