QUANTIFICATION OF OCCUPATIONAL LATEX AEROALLERGENS IN A MEDICAL-CENTER

被引:170
作者
SWANSON, MC
BUBAK, ME
HUNT, LW
YUNGINGER, JW
WARNER, MA
REED, CE
机构
[1] MAYO CLIN & MAYO FDN,DEPT MED,ROCHESTER,MN 55905
[2] MAYO CLIN & MAYO FDN,DEPT PEDIAT,ROCHESTER,MN 55905
[3] MAYO CLIN & MAYO FDN,DEPT ANESTHESIOL,ROCHESTER,MN 55905
[4] MAYO CLIN & MAYO FDN,ALLERG DIS RES LAB,ROCHESTER,MN 55905
关键词
LATEX ALLERGY; GLOVE SENSITIVITY LATEX AEROALLERGEN; OCCUPATIONAL LATEX AEROALLERGEN; LATEX ALLERGEN AIR SAMPLING;
D O I
10.1016/0091-6749(94)90199-6
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
To determine the quantity, variability and mean aerodynamic diameter of latex aeroallergens in a large medical center we collected air samples from work sites by using area and personal breathing zone air samples, and we measured latex allergens by an inhibition assay with IgE antibodies from latex-sensitive individuals. Latex aeroallergen concentrations in 11 areas where powdered latex gloves were frequently used ranged from 13 to 208 ng/m(3), and in areas where powdered latex gloves were never or seldom used, concentrations ranged from 0.3 to 1.8 ng/m(3). Installation and use of a laminar flow glove changing station in one work area did not reduce latex aeroallergen levels. Large quantities of allergen were recovered from used laboratory coats and anesthesia scrub suits and from laboratory surfaces. Later allergen concentrations in personal breathing zone samplers worn by health care workers in areas where powdered gloves were frequently used ranged from 8 to 974 ng/m(3). Exposure likely occurs when gloves are changed and as a result of resuspension from reservoirs of powder in the room and clothing. Latex allergens were found in all particle sizes but were predominant in particles greater than 7 mu m in mass median aerodynamic diameter. Results of electrophoretic immunoblotting showed that the aeroallergens are primarily the higher molecular mass components of the latex glove proteins. Measures to control exposure can be monitored by both area and personal air sampling with this immunochemical approach. Use of gloves with low allergen content or powder-free gloves appears to be more effective than use of a laminar flow glove changing station in reducing aeroallergen levels.
引用
收藏
页码:445 / 451
页数:7
相关论文
共 17 条
  • [1] BEEZHOLD D, 1992, ARCH SURG-CHICAGO, V127, P1354
  • [2] ALLERGIC REACTIONS TO LATEX AMONG HEALTH-CARE WORKERS
    BUBAK, ME
    REED, CE
    FRANSWAY, AF
    YUNGINGER, JW
    JONES, RT
    CARLSON, CA
    HUNT, LW
    [J]. MAYO CLINIC PROCEEDINGS, 1992, 67 (11) : 1075 - 1079
  • [3] AEROALLERGENS IN DAIRY BARNS NEAR COOPERSTOWN, NEW-YORK AND ROCHESTER, MINNESOTA
    CAMPBELL, AR
    SWANSON, MC
    FERNANDEZCALDAS, E
    REED, CE
    MAY, JJ
    PRATT, DS
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1989, 140 (02): : 317 - 320
  • [4] STUDY OF THE ALLERGENIC FRACTIONS OF LATEX
    CHAMBEYRON, C
    DRY, J
    LEYNADIER, F
    PECQUET, C
    THAO, TX
    [J]. ALLERGY, 1992, 47 (02) : 92 - 97
  • [5] LATEX-SPECIFIC PROTEINS CAUSING IMMEDIATE-TYPE CUTANEOUS, NASAL, BRONCHIAL, AND SYSTEMIC REACTIONS
    JAEGER, D
    KLEINHANS, D
    CZUPPON, AB
    BAUR, X
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1992, 89 (03) : 759 - 768
  • [6] CLEAVAGE OF STRUCTURAL PROTEINS DURING ASSEMBLY OF HEAD OF BACTERIOPHAGE-T4
    LAEMMLI, UK
    [J]. NATURE, 1970, 227 (5259) : 680 - +
  • [7] MAIBACH HI, 1988, ALLERGY PRINCIPLES P, P1429
  • [8] OWABY DR, 1991, AJR AM J ROENTGENOL, V156, P983
  • [9] LATEX ANTIGENS
    SLATER, JE
    CHHABRA, SK
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1992, 89 (03) : 673 - 678
  • [10] RUBBER ANAPHYLAXIS
    SLATER, JE
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1989, 320 (17) : 1126 - 1130