PHOTOLUMINESCENCE LIFETIME MICROSCOPE SPECTROMETER BASED ON TIME-CORRELATED SINGLE-PHOTON COUNTING WITH AN AVALANCHE-DIODE DETECTOR

被引:36
作者
LOUIS, TA
RIPAMONTI, G
LACAITA, A
机构
[1] HERIOT WATT UNIV,DEPT PHYS,EDINBURGH EH14 4AS,MIDLOTHIAN,SCOTLAND
[2] POLITECN MILAN,DIPARTIMENTO ELETTRON,I-20133 MILAN,ITALY
[3] CNR,CTR ELETTRON QUANTIST & STRUMENTAZ,I-20133 MILAN,ITALY
关键词
D O I
10.1063/1.1141885
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A photoluminescence lifetime microscope spectrometer (PLμS) based on time-correlated single-photon counting (TCSPC) with a single-photon avalanche diode (SPAD) detector was developed for the investigation of the microscopic spatial fluctuations of the minority-carrier lifetime and other material parameters in gallium arsenide (GaAs) and related compound semiconductors. The high sensitivity of the TCSPC technique is essential for time-resolved photoluminescence (TRPL) measurements with a spatial resolution of the order of a few micrometers. The spatial resolution of the PLμS is compatible with the diffusion length in GaAs substrates or the dimensions of small, highly integrated GaAs devices. The PLμS is the first instrument of its kind based entirely on solid-state components, i.e., a gain-switched diode laser for pulsed excitation and an avalanche diode for single-photon detection. It is explained why, in samples dominated by nonradiative linear recombination, the relatively large excitation pulse width of the diode laser compared to a synchronously pumped dye laser does not adversely affect the timing accuracy of the measured decay time constants. It was previously shown that, by using nonlinear least-squares iterative convolution analysis, a TCSPC instrument with an instrumental response width of 70 ps (FWHM) is capable of accurately measuring fluorescence decay time constants down to 10 ps with ±2 ps timing accuracy. The PLμS is designed to take full advantage of the high repetition rates, up to 100 MHz, typical for mode-locked laser sources or gain-switched diode lasers. The data-acquisition time for a complete decay curve containing typically several hundred thousand counts is thus reduced to a few seconds. Hence, the PLμS is, in principle, suitable for scanning operation and topographical imaging.
引用
收藏
页码:11 / 22
页数:12
相关论文
共 48 条
[1]  
AHRENKIEL K, 1988, SOL CELLS, V24, P339
[2]  
AHRENKIEL RK, 1988, CURRENT TOPICS PHOTO, V3, P1
[3]  
ANDREONI A, 1982, SPRINGER SERIES CHEM, V23
[4]   TIME-CORRELATED SINGLE-PHOTON COUNTING FLUORESCENCE DECAY STUDIES AT 930 NM USING SPARK SOURCE EXCITATION [J].
BIRCH, DJS ;
HUNGERFORD, G ;
NADOLSKI, B ;
IMHOF, RE ;
DUTCH, AD .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1988, 21 (09) :857-862
[5]  
BOURRET ED, 1987, DEFECT RECOGNITION I, P95
[6]  
CANONICA S, 1985, ANAL INSTRUM, V14, P331
[7]   RECOMBINATION DYNAMICS OF CARRIERS IN GAAS-GAALAS QUANTUM-WELL STRUCTURES [J].
CHRISTEN, J ;
BIMBERG, D .
SURFACE SCIENCE, 1986, 174 (1-3) :261-271
[8]   20-PS TIMING RESOLUTION WITH SINGLE-PHOTON AVALANCHE-DIODES [J].
COVA, S ;
LACAITA, A ;
GHIONI, M ;
RIPAMONTI, G ;
LOUIS, TA .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (06) :1104-1110
[9]   AVALANCHE SEMICONDUCTOR DETECTOR FOR SINGLE OPTICAL PHOTONS WITH A TIME RESOLUTION OF 60 PS [J].
COVA, S ;
RIPAMONTI, G ;
LACAITA, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 253 (03) :482-487
[10]   ACTIVE-QUENCHING AND GATING CIRCUITS FOR SINGLE-PHOTON AVALANCHE-DIODES (SPADS) [J].
COVA, S ;
LONGONI, A ;
RIPAMONTI, G .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1982, 29 (01) :599-601