OPTIMAL DATA-ACQUISITION FOR VOLUMETRIC INTRACORONARY ULTRASOUND

被引:21
作者
DHAWALE, PJ
WILSON, DL
HODGSON, JM
机构
[1] UNIV HOSP CLEVELAND,DIV CARDIOL,2074 ABINGTON RD,CLEVELAND,OH 44106
[2] CASE WESTERN RESERVE UNIV,DEPT BIOMED ENGN,CLEVELAND,OH 44106
来源
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS | 1994年 / 32卷 / 03期
关键词
CORONARY ARTERY DISEASE; ULTRASOUND DIAGNOSIS; CARDIAC CATHETERIZATION;
D O I
10.1002/ccd.1810320321
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Three-dimensional analysis using intracoronary ultrasound (ICUS) pull-back data provides the unique ability to quantitate lumen and atherosclerotic plaque volumes. Optimal data acquisition parameters for volumetric acquisition were established using simulations on computer phantoms of stenotic arteries. Eleven computer phantoms were generated using cross-sectional area data from quantitative angiography of stenotic coronary arteries. Three methods of data acquisition were simulated: conventional manual pull-back; motorized pull-back; and manual pull-back with measured displacement. Effects of pull-back velocity and cardiac gating on cross-sectional area profiles and volumes were studied. Cardiac gating eliminated errors introduced by vessel deformation within a cardiac cycle. With cardiac gating, pull-backs with mean velocities up to 1.2 mm/sec allowed reconstruction of cross-sectional area profiles within 5% RMS error. With faster pull-backs, cardiac gating resulted in sparse spatial sampling and significant errors in cross-sectional area profiles. The accuracy of both motorized and measured required equal displacements of the catheter proximal and distal ends. This assumption was validated with in vitro experiments where X-ray fluoroscopy was used to measure the displacement of the imaging tip. Excellent correlation was found between the two displacements (r = 0.99). Finally, slow pull-backs were performed by 3 operators, and pull-back velocities were measured. It was found that mean pull-back velocities as low as 0.8 mm/sec were achievable. From our simulations, we predict that accurate volumetric analysis requires cardiac gated, calibrated, slow (< 1.2 mm/sec) pull-backs. (C) 1994 Wiley-Liss, Inc.
引用
收藏
页码:288 / 299
页数:12
相关论文
共 19 条
  • [1] PROPAGATION VELOCITY AND REFLECTION OF PRESSURE WAVES IN THE CANINE CORONARY-ARTERY
    ARTS, T
    KRUGER, RTI
    VANGERVEN, W
    LAMBREGTS, JAC
    RENEMAN, RS
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1979, 237 (04): : H469 - H474
  • [2] Burden R. L., 1985, NUMERICAL ANAL
  • [3] CAVAYE DM, 1991, AM SURGEON, V57, P751
  • [4] CAVAYE DM, 1992, ENDOVASC SURG, V72, P823
  • [5] INVITRO VALIDATION OF 3-DIMENSIONAL INTRAVASCULAR ULTRASOUND FOR THE EVALUATION OF ARTERIAL INJURY AFTER BALLOON ANGIOPLASTY
    COY, KM
    PARK, JC
    FISHBEIN, MC
    LAAS, T
    DIAMOND, GA
    ADLER, L
    MAURER, G
    SIEGEL, RJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (03) : 692 - 700
  • [6] DHAWALE PJ, 1993, CIRCULATION, V88, P550
  • [7] DHAWALE PJ, 1983, P IEEE ENG MED BIOL, V1, P204
  • [8] DHAWALE PJ, 1992, P COMPUT CRDIOL, P30
  • [9] HETEROGENEITY IN GEOMETRICAL ALTERATIONS OF MAIN BRANCHES OF LEFT CORONARY-ARTERY INDUCED BY INCREASE IN VENTRICLE VOLUME
    GEROVA, M
    BARTA, E
    STOLARIK, M
    GERO, J
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1992, 262 (04): : H1049 - H1053
  • [10] COMPENSATORY ENLARGEMENT OF HUMAN ATHEROSCLEROTIC CORONARY-ARTERIES
    GLAGOV, S
    WEISENBERG, E
    ZARINS, CK
    STANKUNAVICIUS, R
    KOLETTIS, GJ
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1987, 316 (22) : 1371 - 1375