EVALUATION OF THE HARVARD OZONE PASSIVE SAMPLER ON HUMAN-SUBJECTS INDOORS

被引:39
作者
LIU, LJS
OLSON, MP
ALLEN, GA
KOUTRAKIS, P
MCDONNELL, WF
GERRITY, TR
机构
[1] HARVARD UNIV,SCH PUBL HLTH,665 HUNTINGTON AVE,BOSTON,MA 02115
[2] UNIV N CAROLINA,US EPA,CHAPEL HILL,NC 27514
关键词
D O I
10.1021/es00054a024
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Our study examined the performance of the Harvard ozone passive sampler, providing comprehensive evaluation results and investigation of ozone behavior around the human body through a series of chamber and indoor field tests. The results demonstrated excellent agreement between the passive and continuous measurements for both personal and indoor monitoring in an environmental exposure chamber. An ozone concentration gradient around the human body was found, most likely due to depletion and dilution effects. When the passive sampler was attached to a polystyrene backing plate and worn on the chest, ozone depletion on clothing was significantly reduced. Results from additional indoor field tests support those from the chamber study. The effective collection rate for personal samplers with backing placed on the chest was comparable for both chamber and field conditions, while the effective collection rate for microenvironmental samplers was lower in the field.
引用
收藏
页码:915 / 923
页数:9
相关论文
共 15 条
  • [1] ACCUMULATED EXPOSURE TO OZONE AND MEASUREMENT OF HEALTH-EFFECTS IN CHILDREN AND COUNSELORS AT 2 SUMMER CAMPS
    BERRY, M
    LIOY, PJ
    GELPERIN, K
    BUCKLER, G
    KLOTZ, J
    [J]. ENVIRONMENTAL RESEARCH, 1991, 54 (02) : 135 - 150
  • [2] COLOME S, 1993, 92364 SON TECHN INC
  • [3] Fleiss J. L., 1986, RELIABILITY MEASUREM
  • [4] PULMONARY-FUNCTION AND SYMPTOM RESPONSES AFTER 6.6-HOUR EXPOSURE TO 0.12 PPM OZONE WITH MODERATE EXERCISE
    FOLINSBEE, LJ
    MCDONNELL, WF
    HORSTMAN, DH
    [J]. JAPCA-THE INTERNATIONAL JOURNAL OF AIR POLLUTION CONTROL AND HAZARDOUS WASTE MANAGEMENT, 1988, 38 (01): : 28 - 35
  • [5] DESIGN AND PERFORMANCE OF A SYSTEM TO CONTROL CONCENTRATIONS OF COMMON GASEOUS AIR-POLLUTANTS WITHIN ENVIRONMENTAL LABORATORIES USED FOR HUMAN EXPOSURE STUDIES
    GLOVER, DE
    BERNTSEN, JH
    CRIDER, WL
    STRONG, AA
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-ENVIRONMENTAL SCIENCE AND ENGINEERING & TOXIC AND HAZARDOUS SUBSTANCE CONTROL, 1981, 16 (05): : 501 - 522
  • [6] Kinney P.L., 1993, APPL OCCUP ENV HYG, V8, P267
  • [7] COMPARISON OF CHEMILUMINESCENCE AND ULTRAVIOLET OZONE MONITOR RESPONSES IN THE PRESENCE OF HUMIDITY AND PHOTOCHEMICAL POLLUTANTS
    KLEINDIENST, TE
    HUDGENS, EE
    SMITH, DF
    MCELROY, FF
    BUFALINI, JJ
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1993, 43 (02): : 213 - 222
  • [8] MEASUREMENT OF AMBIENT OZONE USING A NITRITE-COATED FILTER
    KOUTRAKIS, P
    WOLFSON, JM
    BUNYAVIROCH, A
    FROEHLICH, SE
    HIRANO, K
    MULIK, JD
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (03) : 209 - 214
  • [9] AN AIR-QUALITY DATA-ANALYSIS SYSTEM FOR INTERRELATING EFFECTS, STANDARDS, AND NEEDED SOURCE REDUCTIONS .11. A LOGNORMAL MODEL RELATING HUMAN LUNG-FUNCTION DECREASE TO O3 EXPOSURE
    LARSEN, RI
    MCDONNELL, WF
    HORSTMAN, DH
    FOLINSBEE, LJ
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1991, 41 (04): : 455 - 459
  • [10] LEE KY, 1992, J EXPO ANAL ENV EPID, V2, P207