Equations for the calculation of peak parameters (area, mean, variance, skewness, excess, number of theoretical plates (N) and maximum number of theoretical plates) from graphically measurable variables (maximum height, retention time, width and asymmetry factor) were developed by using the log-normal distribution function as a model for chromatographic peaks. The equations were tested for a series of 50 experimental peaks obtained by gas and liquid chromatography, giving parameters consistent with those obtained by direct profile integration with numerical methods. The equations were compared with those derived from the exponentially modified Gaussian function. The greatest discrepancies between the two models were found in the results from the equations for skewness and excess. The differences were small (almost-equal-to 5%) at high peak asymmetry (a > 2.5) but became important (skewness almost-equal-to 60%, excess > 100%) for nearly symmetric peaks (a almost-equal-to 1.1); the log-normal equations gave values closer to the parameters obtained by direct integration. The log-normal N values were 4-16% higher than those obtained with the EMG function and the log-normal model provided more realistic estimates for maximum N.
引用
收藏
页码:59 / 70
页数:12
相关论文
共 28 条
[1]   COMPUTER RESOLUTION OF UNRESOLVED CONVOLUTED GAS-CHROMATOGRAPHIC PEAKS [J].
ANDERSON, AH ;
GIBB, TC ;
LITTLEWO.AB .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1970, 8 (11) :640-&
[2]   EFFECT OF BASELINE ERRORS ON THE CALCULATION OF STATISTICAL MOMENTS OF TAILED CHROMATOGRAPHIC PEAKS [J].
ANDERSON, DJ ;
WALTERS, RR .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1984, 22 (08) :353-359
[3]   GRAPHICAL-METHOD FOR OBTAINING RETENTION TIME AND NUMBER OF THEORETICAL PLATES FROM TAILED CHROMATOGRAPHIC PEAKS [J].
BARBER, WE ;
CARR, PW .
ANALYTICAL CHEMISTRY, 1981, 53 (12) :1939-1942
[4]  
BIDLINGMEYER BA, 1984, ANAL CHEM, V56, P1583
[5]  
BURY KV, 1975, STATISTICAL MODELS A
[6]   EFFECT OF PEAK SENSING AND RANDOM NOISE ON PRECISION AND ACCURACY OF STATISTICAL MOMENT ANALYSES FROM DIGITAL CHROMATOGRAPHIC DATA [J].
CHESLER, SN ;
CRAM, SP .
ANALYTICAL CHEMISTRY, 1971, 43 (14) :1922-&
[7]   ASSESSMENT OF THE HEIGHT EQUIVALENT TO A THEORETICAL PLATE IN LIQUID-CHROMATOGRAPHY [J].
COLMSJO, AL ;
ERICSSON, MW .
JOURNAL OF CHROMATOGRAPHY, 1987, 398 :63-71
[8]   MODIFYING THE GAUSSIAN PEAK SHAPE WITH MORE THAN ONE TIME CONSTANT [J].
DELLEY, R .
ANALYTICAL CHEMISTRY, 1986, 58 (11) :2344-2346
[9]   A REVIEW OF THE EXPONENTIALLY MODIFIED GAUSSIAN (EMG) FUNCTION - EVALUATION AND SUBSEQUENT CALCULATION OF UNIVERSAL DATA [J].
FOLEY, JP ;
DORSEY, JG .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1984, 22 (01) :40-46
[10]   EQUATIONS FOR CHROMATOGRAPHIC PEAK MODELING AND CALCULATION OF PEAK AREA [J].
FOLEY, JP .
ANALYTICAL CHEMISTRY, 1987, 59 (15) :1984-1987