DESIGN AND TEST OF A PROTOTYPE GAS-SAMPLING ELECTROMAGNETIC CALORIMETER OF HIGH GRANULARITY FOR THE CPLEAR EXPERIMENT

被引:4
作者
ADLER, R
BACKENSTOSS, G
BLOCH, P
DAMIANOGLOU, D
DECHELETTE, P
DROGE, M
FELDER, C
FETSCHER, W
FIDECARO, M
GARRETA, D
GERBER, HJ
GUMPLINGER, P
JOHNER, HU
KERN, J
KOKKAS, P
MALL, U
NANNI, F
PAVLOPOULOS, P
RENEVEY, M
SANTONI, C
SCHOPPER, A
TAUSCHER, L
WENDLER, H
PAGELS, B
WITZIG, C
机构
[1] CERN, CH-1211 GENEVA 23, SWITZERLAND
[2] INP, NCSR DEMOCRITOS, ATHENS, GREECE
[3] UNIV FRIBOURG, CH-1700 FRIBOURG, SWITZERLAND
[4] UNIV IOANNINA, IOANNINA, GREECE
[5] ARISTOTELIAN UNIV SALONIKA, Thessaloniki, GREECE
[6] SWISS FED INST TECHNOL, IMP, CH-8092 ZURICH, SWITZERLAND
[7] UNIV ATHENS, ATHENS, GREECE
[8] BOSTON UNIV, BOSTON, MA 02215 USA
[9] UNIV COIMBRA, P-3400 COIMBRA, PORTUGAL
[10] DELFT UNIV TECHNOL, DELFT, NETHERLANDS
[11] UNIV LIVERPOOL, LIVERPOOL L69 3BX, ENGLAND
[12] EDVARD KARDELJ UNIV, J STEFAN INST, YU-61000 LJUBLJANA, SLOVENIA
[13] EDVARD KARDELJ UNIV, DEPT PHYS, YU-61000 LJUBLJANA, SLOVENIA
[14] CNRS, CPPM, IN2P3, F-13003 MARSEILLE, FRANCE
[15] UNIV AIX MARSEILLE 2, F-13007 MARSEILLE, FRANCE
[16] CNRS, CSNSM, IN2P3, F-91405 ORSAY, FRANCE
[17] PAUL SCHERRER INST, VILLIGEN, SWITZERLAND
[18] MSI, STOCKHOLM, SWEDEN
[19] CENS, DAPNIA SPP, F-91190 GIF SUR YVETTE, FRANCE
关键词
D O I
10.1016/0168-9002(92)90055-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have designed and tested a gas-sampling calorimeter of high granularity as a prototype for the electromagnetic calorimeter of the CPLEAR experiment. The prototype calorimeter, consisting of 18 layers of 1.5 mm thin lead converters interleaved with a total of 1152 high-gain tubes and 2304 pick-up strips, was tested in a tagged photon beam with photons in the energy range of 50 to 350 MeV. It well fulfilled the requirements of a good detection efficiency for photons above 50 MeV with a spatial resolution sigma almost-equal-to 5 mm for the photon conversion point and an energy resolution sigma(E)/E almost-equal-to 15% square-root E[GeV].
引用
收藏
页码:458 / 466
页数:9
相关论文
共 5 条
[1]  
ADLER R, 1991, LEAP 90, P414
[2]   DEVELOPMENT OF SMALL HIGH-GAIN TUBES FOR THE ELECTROMAGNETIC CALORIMETER OF THE CPLEAR EXPERIMENT [J].
BLOCH, P ;
DECHELETTE, P ;
FIDECARO, M ;
GARRETA, D ;
JOHNER, HU ;
NANNI, F ;
RENEVEY, M ;
SCHOPPER, A ;
WENDLER, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 297 (1-2) :126-132
[3]  
BRUN R, 1984, CERN DDEE841
[4]   FAST AND FLEXIBLE DATA ACQUISITION-SYSTEM FOR MULTIWIRE PROPORTIONAL CHAMBERS AND OTHER DETECTORS [J].
LINDSAY, JB ;
MILLERIN, C ;
TARLE, JC ;
VERWEIJ, H ;
WENDLER, H .
NUCLEAR INSTRUMENTS & METHODS, 1978, 156 (1-2) :329-333
[5]  
SCHOPPER A, 1989, THESIS U BASEL