Validity and reliability of a field technique for sweat Na+ and K+ analysis during exercise in a hot-humid environment

被引:48
作者
Baker, Lindsay B. [1 ]
Ungaro, Corey T. [1 ]
Barnes, Kelly A. [1 ]
Nuccio, Ryan P. [1 ]
Reimel, Adam J. [1 ]
Stofan, John R. [1 ]
机构
[1] Gatorade Sports Sci Inst, 617 W Main St, Barrington, IL 60010 USA
来源
PHYSIOLOGICAL REPORTS | 2014年 / 2卷 / 05期
关键词
Compact electrolyte analyzers; Horiba; regional sweat collection; sweat patches;
D O I
10.14814/phy2.12007
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
This study compared a field versus reference laboratory technique for extracting (syringe vs. centrifuge) and analyzing sweat [Na+] and [K+] ( compact Horiba B-722 and B-731, HORIBA vs. ion chromatography, HPLC) collected with regional absorbent patches during exercise in a hot-humid environment. Sweat samples were collected from seven anatomical sites on 30 athletes during 1-h cycling in a heat chamber (33 degrees C, 67% rh). Ten minutes into exercise, skin was cleaned/dried and two sweat patches were applied per anatomical site. After removal, one patch per site was centrifuged and sweat was analyzed with HORIBA in the heat chamber (CENTRIFUGE HORIBA) versus HPLC (CENTRIFUGE HPLC). Sweat from the second patch per site was extracted using a 5-mL syringe and analyzed with HORIBA in the heat chamber (SYRINGE HORIBA) versus HPLC (SYRINGE HPLC). CENTRIFUGE HORIBA, SYRINGE HPLC, and SYRINGE HORIBA were highly related to CENTRIFUGE HPLC ([ Na+]: ICC = 0.96, 0.94, and 0.93, respectively; [K+]: ICC = 0.87, 0.92, and 0.84, respectively), while mean differences from CENTRIFUGE HPLC were small but usually significant ([Na+]: 4.7 +/- 7.9 mEql/L, -2.5 +/- 9.3 mEq/L, 4.0 +/- 10.9 mEq/L (all P < 0.001), respectively; [K+]: 0.44 +/- 0.52 mEq/L (P < 0.001), 0.01 +/- 0.49 mEq/L (P = 0.77), 0.50 +/- 0.48 mEq/L (P < 0.001), respectively). On the basis of typical error of the measurement results, sweat [Na+] and [K+] obtained with SYRINGE HORIBA falls within +/- 15.4 mEq/L and +/- 0.68 mEq/L, respectively, of CENTRIFUGE HPLC 95% of the time. The field (SYRINGE HORIBA) method of extracting and analyzing sweat from regional absorbent patches may be useful in obtaining sweat [Na (+)] when rapid estimates in a hot-humid field setting are needed.
引用
收藏
页数:11
相关论文
共 27 条
[1]   INFLUENCE OF ACCLIMATIZATION ON SWEAT SODIUM CONCENTRATION [J].
ALLAN, JR ;
WILSON, CG .
JOURNAL OF APPLIED PHYSIOLOGY, 1971, 30 (05) :708-&
[2]   Exertional heat illness during training and competition [J].
Armstrong, Lawrence E. ;
Casa, Douglas J. ;
Millard-Stafford, Mindy ;
Moran, Daniel S. ;
Pyne, Scott W. ;
Roberts, Wiliam O. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2007, 39 (03) :556-572
[3]  
Armstrong LE., 2009, ATHL TRAIN SPORTS HL, V1, P169, DOI [10.3928/19425864-20090625-06, DOI 10.3928/19425864-20090625-06]
[4]   Comparison of regional patch collection vs. whole body washdown for measuring sweat sodium and potassium loss during exercise [J].
Baker, Lindsay B. ;
Stofan, John R. ;
Hamilton, Adam A. ;
Horswill, Craig A. .
JOURNAL OF APPLIED PHYSIOLOGY, 2009, 107 (03) :887-895
[5]   Heat cramps: fluid and electrolyte challenges during tennis in the heat [J].
Bergeron, MF .
JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2003, 6 (01) :19-27
[6]   VALIDITY OF THE WESCORS SWEAT CONDUCTIVITY ANALYZER FOR THE ASSESSMENT OF SWEAT ELECTROLYTE CONCENTRATIONS [J].
BOISVERT, P ;
CANDAS, V .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1994, 69 (02) :176-178
[7]   Fluid and fuel intake during exercise [J].
Coyle, EF .
JOURNAL OF SPORTS SCIENCES, 2004, 22 (01) :39-55
[8]  
Dwyer G. B., 2008, ACSMS HLTH REL PHYS, P129
[9]   Validity and reliability of the Horiba C-122 compact sodium analyzer in sweat samples of athletes [J].
Goulet, Eric D. B. ;
Dion, Tommy ;
Myette-Cote, Etienne .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (10) :3479-3485
[10]   CLINICAL-EVALUATION OF THE MACRODUCT SWEAT COLLECTION SYSTEM AND CONDUCTIVITY ANALYZER IN THE DIAGNOSIS OF CYSTIC-FIBROSIS [J].
HAMMOND, KB ;
TURCIOS, NL ;
GIBSON, LE .
JOURNAL OF PEDIATRICS, 1994, 124 (02) :255-260