ADDITIONAL STUDY OF THE DIRECT METHANOL-LSC METHOD FOR LOW-LEVEL C-14 MEASUREMENT

被引:5
作者
SHIBATA, S [1 ]
KAWANO, E [1 ]
NAKABAYASHI, T [1 ]
YAMADA, O [1 ]
机构
[1] KYOTO SANGYO UNIV,FAC SCI,KITA KU,KYOTO 603,JAPAN
关键词
D O I
10.1016/0969-8043(93)90105-J
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
When methanol for C-14 liquid scintillation measurement is prepared directly from carbonized samples through combustion and LiAlH4 reduction, solvent-originating methanol is likely to form in small amounts. We have modified the combustion condition to use an N2-O2 mixture of minimized O2 content, and have made negligible the formation of solvent-originating methanol. Measurements of C-14 concentrations in rice grains, anthracite and NIST standard sample demonstrate the validity of our method as a convenient technique for low-level C-14 measurement.