VALIDATION OF A METHOD FOR CHOICE OF PACING MODE IN CAROTID-SINUS SYNDROME WITH OR WITHOUT SINUS BRADYCARDIA

被引:38
作者
BRIGNOLE, M [1 ]
MENOZZI, C [1 ]
LOLLI, G [1 ]
ODDONE, D [1 ]
GIANFRANCHI, L [1 ]
BERTULLA, A [1 ]
机构
[1] HOSP LAVAGNA,SERV CARDIOL,ELECTROPHYSIOL & PACING LAB,LAVAGNA,ITALY
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1991年 / 14卷 / 02期
关键词
CAROTID SINUS SYNDROME; CARDIAC PACING; SYNCOPE; SINUS NODE DYSFUNCTION; CARDIO-INHIBITION; VASODEPRESSOR;
D O I
10.1111/j.1540-8159.1991.tb05090.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A new method for selection of the pacing mode in 60 consecutive patients with severe cardioinhibitory or mixed carotid sinus syndrome was prospectively validated. DDD pacing was preferred for 26 patients with: (1) the cardioinhibitory form and who had symptomatic pacemaker effect; (2) mixed type I form, (cardioinhibitory and vasodepressor) with symptomatic pacemaker effect, ventriculoatrial conduction or orthostatic hypotension; (3) mixed type II; or (4) severe bradycardia. VVI pacing was selected in the remaining 34 patients without these symptoms. During a 32 +/- 10 month follow-up period syncope and severe dizziness presisted in five patients in the VVI group (15%) and in three patients in the DDD group (12%). Symptomatic relief occurred in 87% (52/60) of patients. Minor symptoms persisted in 47% of the VVI group and 42% of the DDD group. No patient developed cardiac insufficiency or intolerance to pacing. During a 2-month duration a single-blind, randomized, cross-over study compared VVI and DDD pacing, 69% of the patients programmed from DDD to VVI suffered more frequent, severe, and intolerable symptoms. (1) Thirty four of 60 patients (57% of the entire group) in whom VVI pacing was satisfactory were identified prior to pacemaker implant. In the remainder, VVI pacing was contraindicated as it produced frequent side effects. (2) The preimplant predictive value that VVI pacing would be successful was 85% for those eventually receiving VVI pacemakers and the preimplant predictive value that VVI pacing would fail was 69% for those who underwent DDD implant.
引用
收藏
页码:196 / 203
页数:8
相关论文
共 20 条
  • [1] CAROTID-SINUS HYPERSENSITIVITY - EVALUATION OF THE VASODEPRESSOR COMPONENT
    ALMQUIST, A
    GORNICK, C
    BENSON, DW
    DUNNIGAN, A
    BENDITT, DG
    [J]. CIRCULATION, 1985, 71 (05) : 927 - 936
  • [2] BRIGNOLE M, 1986, Giornale Italiano di Cardiologia, V16, P643
  • [3] NATURAL AND UNNATURAL HISTORY OF PATIENTS WITH SEVERE CAROTID-SINUS HYPERSENSITIVITY - A PRELIMINARY-STUDY
    BRIGNOLE, M
    MENOZZI, C
    LOLLI, G
    SARTORE, B
    BARRA, M
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (11): : 1628 - 1635
  • [4] VENTRICULAR AND DUAL CHAMBER PACING FOR TREATMENT OF CAROTID-SINUS SYNDROME
    BRIGNOLE, M
    SARTORE, B
    BARRA, M
    MENOZZI, C
    LOLLI, G
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (04): : 582 - 590
  • [5] IS DDD SUPERIOR TO VVI PACING IN MIXED CAROTID-SINUS SYNDROME - AN ACUTE AND MEDIUM-TERM STUDY
    BRIGNOLE, M
    SARTORE, B
    BARRA, M
    MENOZZI, C
    LOLLI, G
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (11): : 1902 - 1910
  • [6] BRIGNOLE M, 1985, Giornale Italiano di Cardiologia, V15, P971
  • [7] BRIGNOLE M, 1989, PACE, V12, P1153
  • [8] CAROTID-SINUS REFLEX IN PATIENTS UNDERGOING CORONARY ANGIOGRAPHY - RELATIONSHIP OF DEGREE AND LOCATION OF CORONARY-ARTERY DISEASE TO RESPONSE TO CAROTID-SINUS MASSAGE
    BROWN, KA
    MALONEY, JD
    SMITH, HC
    HARTZLER, GO
    ILSTRUP, DM
    [J]. CIRCULATION, 1980, 62 (04) : 697 - 703
  • [9] SYNCOPE IN THE ELDERLY
    LIPSITZ, LA
    [J]. ANNALS OF INTERNAL MEDICINE, 1983, 99 (01) : 92 - 105
  • [10] CAROTID-SINUS HYPERSENSITIVITY - BENEFICIAL-EFFECTS OF DUAL-CHAMBER PACING
    MADIGAN, NP
    FLAKER, GC
    CURTIS, JJ
    REID, J
    MUELLER, KJ
    MURPHY, TJ
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (08) : 1034 - 1040