3-DIMENSIONAL ECHOCARDIOGRAPHY - IN-VIVO VALIDATION FOR LEFT-VENTRICULAR VOLUME AND FUNCTION

被引:131
作者
SIU, SC
RIVERA, JM
GUERRERO, JL
HANDSCHUMACHER, MD
LETHOR, JP
WEYMAN, AE
LEVINE, RA
PICARD, MH
机构
[1] MASSACHUSETTS GEN HOSP, CARDIAC UNIT, CARDIAC ULTRASOUND LAB, FRUIT ST, BOSTON, MA 02114 USA
[2] HARVARD UNIV, SCH MED, BOSTON, MA 02115 USA
关键词
ECHOCARDIOGRAPHY; LEFT VENTRICLE; ULTRASOUND;
D O I
10.1161/01.CIR.88.4.1715
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Current two-dimensional quantitative echocardiographic methods of volume assessment require image acquisition from standardized scanning planes. Left ventricular volume and ejection fraction are then calculated by assuming ventricular symmetry and geometry. These assumptions may not be valid in distorted ventricles. Three-dimensional echocardiography can quantify left ventricular volume without the limitations imposed by the assumptions of two-dimensional methods. We have developed a three-dimensional system that automatically integrates two-dimensional echocardiographic images and their positions in real time and calculates left ventricular volume directly from traced endocardial contours without geometric assumptions. Methods and Results. To study the accuracy of this method in quantifying left ventricular volume and performance in vivo, a canine model was developed in which instantaneous left ventricular volume can be measured directly with an intracavitary balloon connected to an external column. Ten dogs were studied at 84 different cavity volumes (4 to 85 cm3) and in conditions of altered left ventricular shape produced by either coronary occlusion or right ventricular volume overload. To demonstrate clinical feasibility, 19 adult human subjects were then studied by this method for quantification of stroke volume. Left ventricular volume, stroke volume, and ejection fraction calculated by three-dimensional echocardiography correlated well with directly measured values (r=.98, .96, .96 for volume, stroke volume, and ejection fraction, respectively) and agreed closely with them (mean difference, -0.78 cm3, -0.60 cm3, -0.32%). In humans, there was a good correlation (r=.94, SEE=4.29 cm3) and agreement (mean difference, -0.98+/-4.2 cm3) between three-dimensional echocardiography and Doppler-derived stroke volumes. Conclusions. Three-dimensional echocardiography allows accurate assessment of left ventricular volume and systolic function.
引用
收藏
页码:1715 / 1723
页数:9
相关论文
共 35 条
  • [1] RESULTS OF CORONARY-ARTERY SURGERY IN PATIENTS WITH POOR LEFT-VENTRICULAR FUNCTION (CASS)
    ALDERMAN, EL
    FISHER, LD
    LITWIN, P
    KAISER, GC
    MYERS, WO
    MAYNARD, C
    LEVINE, F
    SCHLOSS, M
    [J]. CIRCULATION, 1983, 68 (04) : 785 - 795
  • [2] END-SYSTOLIC VOLUME AS A PREDICTOR OF POSTOPERATIVE LEFT-VENTRICULAR PERFORMANCE IN VOLUME OVERLOAD FROM VALVULAR REGURGITATION
    BOROW, KM
    GREEN, LH
    MANN, T
    SLOSS, LJ
    BRAUNWALD, E
    COLLINS, JJ
    COHN, L
    GROSSMAN, W
    [J]. AMERICAN JOURNAL OF MEDICINE, 1980, 68 (05) : 655 - 663
  • [3] EARLY CHANGES IN LEFT-VENTRICULAR SIZE AND FUNCTION AFTER CORRECTION OF LEFT-VENTRICULAR VOLUME OVERLOAD
    BOUCHER, CA
    BINGHAM, JB
    OSBAKKEN, MD
    OKADA, RD
    STRAUSS, HW
    BLOCK, PC
    LEVINE, FH
    PHILLIPS, HR
    POHOST, GM
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1981, 47 (05) : 991 - 1004
  • [4] NON-GEOMETRIC DETERMINATION OF LEFT-VENTRICULAR VOLUMES FROM EQUILIBRIUM BLOOD POOL SCANS
    DEHMER, GJ
    LEWIS, SE
    HILLIS, LD
    TWIEG, D
    FALKOFF, M
    PARKEY, RW
    WILLERSON, JT
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1980, 45 (02) : 293 - 300
  • [5] THE USE OF BIPLANE ANGIOCARDIOGRAPHY FOR THE MEASUREMENT OF LEFT VENTRICULAR VOLUME IN MAN
    DODGE, HT
    SANDLER, H
    BALLEW, DW
    LORD, JD
    [J]. AMERICAN HEART JOURNAL, 1960, 60 (05) : 762 - 776
  • [6] ACCURATE VOLUME DETERMINATION IN THE ISOLATED EJECTING CANINE LEFT-VENTRICLE BY 2-DIMENSIONAL ECHOCARDIOGRAPHY
    EATON, LW
    MAUGHAN, WL
    SHOUKAS, AA
    WEISS, JL
    [J]. CIRCULATION, 1979, 60 (02) : 320 - 326
  • [7] THE MITRAL-VALVE ORIFICE METHOD FOR NON-INVASIVE TWO-DIMENSIONAL ECHO DOPPLER DETERMINATIONS OF CARDIAC-OUTPUT
    FISHER, DC
    SAHN, DJ
    FRIEDMAN, MJ
    LARSON, D
    VALDESCRUZ, LM
    HOROWITZ, S
    GOLDBERG, SJ
    ALLEN, HD
    [J]. CIRCULATION, 1983, 67 (04) : 872 - 877
  • [8] NEW TECHNIQUE FOR MEASUREMENT OF CARDIAC OUTPUT BY THERMODILUTION IN MAN
    GANZ, W
    DONOSO, R
    MARCUS, HS
    FORRESTER, JS
    SWAN, HJC
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1971, 27 (04) : 392 - +
  • [9] DYNAMIC 3-DIMENSIONAL ECHOCARDIOGRAPHIC RECONSTRUCTION OF THE INTACT HUMAN LEFT-VENTRICLE - TECHNIQUE AND INITIAL OBSERVATIONS IN PATIENTS
    GEISER, EA
    ARIET, M
    CONETTA, DA
    LUPKIEWICZ, SM
    CHRISTIE, LG
    CONTI, CR
    [J]. AMERICAN HEART JOURNAL, 1982, 103 (06) : 1056 - 1065
  • [10] 3-DIMENSIONAL RECONSTRUCTION OF ECHOCARDIOGRAPHIC IMAGES USING THE ROTATION METHOD
    GHOSH, A
    NANDA, NC
    MAURER, G
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1982, 8 (06) : 655 - 661