OPEN-CHANNEL ELECTROCHROMATOGRAPHY ON A MICROCHIP

被引:295
作者
JACOBSON, SC [1 ]
HERGENRODER, R [1 ]
KOUTNY, LB [1 ]
RAMSEY, JM [1 ]
机构
[1] OAK RIDGE NATL LAB,DIV CHEM & ANALYT SCI,OAK RIDGE,TN 37831
关键词
D O I
10.1021/ac00086a024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A glass microchip having a channel with a cross section of 5.6 mu m high and 66 mu m wide was fabricated using standard photolithographic and etching techniques. The surface of the channel was chemically modified with octadecylsilane to function as the stationary phase for open channel chromatography. Electroosmotic now was used to ''load'' the sample into the microchip and to ''pump'' the mobile phase during the experiments. For electric field strengths in the separation column from 27 to 163 V/cm, the linear velocity for the electroosmotic flow ranged from 0.13 to 0.78 mm/s. Detection was performed using direct fluorescence for separation monitoring and indirect fluorescence for void time measurements. Plate heights as low as 4.1 and 5.0 mu m were generated for unretained and retained components, respectively.
引用
收藏
页码:2369 / 2373
页数:5
相关论文
共 26 条
  • [1] ELECTROKINETIC FLOW IN ULTRAFINE CAPILLARY SLITS
    BURGREEN, D
    NAKACHE, FR
    [J]. JOURNAL OF PHYSICAL CHEMISTRY, 1964, 68 (05) : 1084 - &
  • [2] CAPILLARY LIQUID-CHROMATOGRAPHY IN FIELD FLOW FRACTIONATION-TYPE CHANNELS
    GIDDINGS, JC
    CHANG, JP
    MYERS, MN
    DAVIS, JM
    CALDWELL, KD
    [J]. JOURNAL OF CHROMATOGRAPHY, 1983, 255 (JAN): : 359 - 379
  • [3] ROLE OF LATERAL DIFFUSION AS A RATE-CONTROLLING MECHANISM IN CHROMATOGRAPHY
    GIDDINGS, JC
    [J]. JOURNAL OF CHROMATOGRAPHY, 1961, 5 (01): : 46 - &
  • [4] GIDDINGS JC, 1965, DYNAMICS CHROMATOG 1, pCH2
  • [5] Golay M.J.E., 1958, THEORY CHROMATOGRAPH, P36
  • [6] MICROMACHINING A MINIATURIZED CAPILLARY ELECTROPHORESIS-BASED CHEMICAL-ANALYSIS SYSTEM ON A CHIP
    HARRISON, DJ
    FLURI, K
    SEILER, K
    FAN, ZH
    EFFENHAUSER, CS
    MANZ, A
    [J]. SCIENCE, 1993, 261 (5123) : 895 - 897
  • [7] CAPILLARY ELECTROPHORESIS AND SAMPLE INJECTION SYSTEMS INTEGRATED ON A PLANAR GLASS CHIP
    HARRISON, DJ
    MANZ, A
    FAN, ZH
    LUDI, H
    WIDMER, HM
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (17) : 1926 - 1932
  • [8] HIGH-SPEED SEPARATIONS ON A MICROCHIP
    JACOBSON, SC
    HERGENRODER, R
    KOUTNY, LB
    RAMSEY, JM
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (07) : 1114 - 1118
  • [9] EFFECTS OF INJECTION SCHEMES AND COLUMN GEOMETRY ON THE PERFORMANCE OF MICROCHIP ELECTROPHORESIS DEVICES
    JACOBSON, SC
    HERGENRODER, R
    KOUTNY, LB
    WARMACK, RJ
    RAMSEY, JM
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (07) : 1107 - 1113
  • [10] LIQUID-CHROMATOGRAPHY IN OPEN-TUBULAR COLUMNS - THEORY OF COLUMN OPTIMIZATION WITH LIMITED PRESSURE AND ANALYSIS TIME, AND FABRICATION OF CHEMICALLY BONDED REVERSED-PHASE COLUMNS ON ETCHED BOROSILICATE GLASS-CAPILLARIES
    JORGENSON, JW
    GUTHRIE, EJ
    [J]. JOURNAL OF CHROMATOGRAPHY, 1983, 255 (JAN): : 335 - 348