OPERATION OF THE BEAD OF A PRE-METERED COATING DEVICE

被引:12
作者
HENS, J
BOIY, L
机构
[1] Engineering Research, Agfa-Gevaert, Belgium
关键词
LIQUIDS; -; Viscosity;
D O I
10.1016/0009-2509(86)87062-2
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In the literature pre-metered coating devices are described as being governed by viscous and capillary forces only, the radius of curvature of the upper meniscus being the main parameter in their operation. In this paper experimental as well as theoretical evidence is given, indicating that in the conditions prevailing in industrial applications, the liquid flow in a pre-metered coating device is mainly governed by viscous and inertial forces. The most important parameter is the contact length occurring between the liquid and support.
引用
收藏
页码:1827 / 1831
页数:5
相关论文
共 12 条
[1]  
Beguin A. E., 1954, [No title captured], Patent No. [U.S. 2,681,294[P], 2681294]
[2]  
DERYAGIN BV, 1964, FILM COATING THEORY, P37
[3]  
DITTMAN DA, 1977, Patent No. 4001024
[4]  
GALEHOUSE D, 1984, AICHE S COATING FUND
[5]   CAPILLARY-PRESSURE AND VISCOUS PRESSURE-DROP SET BOUNDS ON COATING BEAD OPERABILITY [J].
HIGGINS, BG ;
SCRIVEN, LE .
CHEMICAL ENGINEERING SCIENCE, 1980, 35 (03) :673-682
[6]  
ISHIZAKI I, 1980, Patent No. 2070459
[7]  
LEVI SM, 1966, USPECHI NAUCHN PHOTO, V2, P74
[8]  
LEVICH VG, 1962, PHYSICOCHEM HYDRODYN, P681
[9]  
PITTS E, 1961, J FLUID MECH, V2, P33
[10]   LIMITING FLOW IN A PRE-METERED COATING DEVICE [J].
RUSCHAK, KJ .
CHEMICAL ENGINEERING SCIENCE, 1976, 31 (11) :1057-1060