GAS TRANSFER CHARACTERISTICS OF A NOVEL MEMBRANE BIOREACTOR

被引:12
作者
BEETON, S
MILLWARD, HR
BELLHOUSE, BJ
NICHOLSON, AM
JENKINS, N
KNOWLES, CJ
机构
[1] UNIV KENT,BIOL LAB,CANTERBURY CT2 7NJ,KENT,ENGLAND
[2] LANCASHIRE POLYTECH,SCH APPL BIOL,PRESTON,LANCS,ENGLAND
[3] UNIV OXFORD,DEPT ENGN SCI,MED ENGN UNIT,OXFORD,ENGLAND
关键词
MEMBRANE BIOREACTOR; GAS TRANSFER; PULSATILE FLOW; EXTERNAL OXYGENATION;
D O I
10.1002/bit.260381016
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
We show the design features of a membrane bioreactor based on pulsatile flow across dimpled membranes. Results show an enhanced mass transfer of air of at least five-fold magnitude as compared with flat membranes. An increased working volume from 20 mL to 120 mL reduced the k(L)A at a given Reynolds number because of axial mixing of fluid from the deoxygenated end chamber. The bioreactor was used to supply air to a hybridoma mammalian cell line, and the calculated oxygen uptake showed that high-density cultures could be maintained in a 20 mL, single-dimpled membrane system. Indirect aeration of a 2 L continuous stirred tank reactor, by a double-membrane system, showed that air could be supplied to mammalian cells at cell densities of approximately 4 x 10(6)/mL.
引用
收藏
页码:1233 / 1238
页数:6
相关论文
共 29 条
[1]   MEMBRANES AND BIOREACTORS - A TECHNICAL CHALLENGE IN BIOTECHNOLOGY [J].
BELFORT, G .
BIOTECHNOLOGY AND BIOENGINEERING, 1989, 33 (08) :1047-1066
[2]  
BELLHOUSE BJ, 1973, T AM SOC ART INT ORG, V19, P72
[3]   OXIDATION OF CITRATE ISOCITRATE + CIS-ACONITATE BY ISOLATED MITOCHONDRIA [J].
CHAPPELL, JB .
BIOCHEMICAL JOURNAL, 1964, 90 (02) :225-&
[4]   VISCOUS REDUCTION OF TURBULENT DAMAGE IN ANIMAL-CELL CULTURE [J].
CROUGHAN, MS ;
SAYRE, ES ;
WANG, DIC .
BIOTECHNOLOGY AND BIOENGINEERING, 1989, 33 (07) :862-872
[5]   EXTRACORPOREAL OXYGEN AND CO2 TRANSFER OF A POLYPROPYLENE DIMPLED MEMBRANE LUNG WITH VARIABLE SECONDARY FLOWS - PARTIAL BYPASS IN THE DOG [J].
DORRINGTON, KL ;
GARDAZ, JP ;
BELLHOUSE, BJ ;
SYKES, MK .
JOURNAL OF BIOMEDICAL ENGINEERING, 1986, 8 (01) :36-42
[6]   OXYGEN AND CO2 TRANSFER OF A POLYPROPYLENE DIMPLED MEMBRANE LUNG WITH VARIABLE SECONDARY FLOWS [J].
DORRINGTON, KL ;
RALPH, ME ;
BELLHOUSE, BJ ;
GARDAZ, JP ;
SYKES, MK .
JOURNAL OF BIOMEDICAL ENGINEERING, 1985, 7 (02) :89-99
[7]  
HOPKINSON J, 1983, IMMOBILISED CELLS OR, V4, P89
[8]   OXYGEN-TRANSFER RATES IN A MAMMALIAN-CELL CULTURE BIOREACTOR EQUIPPED WITH A CELL-LIFT IMPELLER [J].
JOHNSON, M ;
ANDRE, G ;
CHAVARIE, C ;
ARCHAMBAULT, J .
BIOTECHNOLOGY AND BIOENGINEERING, 1990, 35 (01) :43-49
[9]   IMPROVED DYNAMIC FILTRATION OF MICROBIAL SUSPENSIONS [J].
KRONER, KH ;
NISSINEN, V ;
ZIEGLER, H .
BIO-TECHNOLOGY, 1987, 5 (09) :921-&
[10]   DAMAGE MECHANISMS OF SUSPENDED ANIMAL-CELLS IN AGITATED BIOREACTORS WITH AND WITHOUT BUBBLE ENTRAINMENT [J].
KUNAS, KT ;
PAPOUTSAKIS, ET .
BIOTECHNOLOGY AND BIOENGINEERING, 1990, 36 (05) :476-483