ANALYSIS OF ENCODING EFFICIENCY IN MR IMAGING OF VELOCITY MAGNITUDE AND DIRECTION

被引:23
作者
CONTURO, TE [1 ]
ROBINSON, BH [1 ]
机构
[1] UNIV WASHINGTON, DEPT CHEM, SEATTLE, WA 98195 USA
关键词
D O I
10.1002/mrm.1910250203
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The efficiency of balanced versus unbalanced techniques for phase‐angle‐based velocity magnitude and direction imaging is investigated. Methods having balanced flow‐encoding gradients (gradients in positive and negative directions with a zero center of gravity) are compared with unbalanced methods. For three‐dimensional imaging, a currently used balanced method is the six‐point technique having opposed gradients pairs for each orthogonal direction. A currently used unbalanced method is a four‐point null technique which has three orthogonal gradients and an additional acquisition having no specific flow encoding to correct the baseline (null) phase. In the gradient‐limited case of slow flow and perfusion. the balanced method is predicted to have higher velocity magnitude‐to‐noise ratio per time (SNRv) by a factor of 1.63, with similar results for velocity direction. In the wraparound‐limited case of faster flows and motions, similar results are found when a null acquisition is added to the balanced method. This results in a seven‐point balanced method having an SNRv, 1.51 times that of the four‐point unbalanced method. If null phases are within the [–π/2, π/2] interval, this additional null acquisition is unnecessary. Other four‐point methods are also considered. These results indicate that, in general, balanced methods have advantages over unbalanced methods for velocity imaging. © 1992 Academic Press, Inc. Copyright © 1992 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:233 / 247
页数:15
相关论文
共 16 条
  • [1] CONSTANTINESCO A, 1984, SOC MAGN RESON MED, P169
  • [2] SIGNAL-TO-NOISE IN PHASE-ANGLE RECONSTRUCTION - DYNAMIC-RANGE EXTENSION USING PHASE REFERENCE OFFSETS
    CONTURO, TE
    SMITH, GD
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 15 (03) : 420 - 437
  • [3] CONTURO TE, 1987, SOC MAGN RESON MED, P25
  • [4] CONTURO TE, 1989, THESIS VANDERBILT U
  • [5] COUNTURO TE, UNPUB MAGN RESON MED
  • [6] COUNTURO TE, 1991, SOC MAGN RESON MED, P813
  • [7] MULTIECHO MAGNETIC-RESONANCE ANGIOGRAPHY
    DUMOULIN, CL
    SOUZA, SP
    FENG, H
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1987, 5 (01) : 47 - 57
  • [8] HENKELMAN RM, 1984, P SOC PHOTO-OPT INST, V486, P192, DOI 10.1117/12.943219
  • [9] Some improvements in weighing and other experimental techniques
    Hotelling, H
    [J]. ANNALS OF MATHEMATICAL STATISTICS, 1944, 15 : 297 - 306
  • [10] MR IMAGING OF INTRAVOXEL INCOHERENT MOTIONS - APPLICATION TO DIFFUSION AND PERFUSION IN NEUROLOGIC DISORDERS
    LEBIHAN, D
    BRETON, E
    LALLEMAND, D
    GRENIER, P
    CABANIS, E
    LAVALJEANTET, M
    [J]. RADIOLOGY, 1986, 161 (02) : 401 - 407