FAST MR-IMAGING - TECHNIQUES AND CLINICAL-APPLICATIONS

被引:79
作者
HAACKE, EM
TKACH, JA
机构
[1] CASE WESTERN RESERVE UNIV,DEPT PHYS,CLEVELAND,OH 44106
[2] CLEVELAND CLIN EDUC FDN,DEPT RADIOL,CLEVELAND,OH 44106
关键词
D O I
10.2214/ajr.155.5.2120964
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Fast MR imaging has matured in the past few years and is now of established value for several aspects of clinical MR imaging. The initial impetus for rapid imaging was to reduce scan times. Today its usefulness includes reducing motion artifacts, improved contrast per unit time, three-dimensional (3-D) imaging, real-time imaging, cine-mode imaging, and flow imaging. The focus of this review is on short-TR steady-state gradient-echo imaging. We discuss the basic sequence design of the mainstream fast techniques. Many important applications exist, including gadopentetate dimeglumine-enhanced MR imaging of the brain and spine, subsecond imaging of real-time applications, myelographic imaging of the spine, cardiac cine-mode imaging; 3-D musculoskeletal (knee) imaging, 3-D pituitary imaging; two-dimensional and 3-D body imaging; 3-D carotid and intravascular imaging, and reformatting 3-D images into arbitrary planes.
引用
收藏
页码:951 / 964
页数:14
相关论文
共 83 条
[1]  
BROOKEMAN JR, 1990, APPL RADIOL JAN, P12
[2]   A NEW STEADY-STATE IMAGING SEQUENCE FOR SIMULTANEOUS ACQUISITION OF 2-MR IMAGES WITH CLEARLY DIFFERENT CONTRASTS [J].
BRUDER, H ;
FISCHER, H ;
GRAUMANN, R ;
DEIMLING, M .
MAGNETIC RESONANCE IN MEDICINE, 1988, 7 (01) :35-42
[3]   CONTRAST IN RAPID MR IMAGING - T1-WEIGHTED AND T2-WEIGHTED IMAGING [J].
BUXTON, RB ;
EDELMAN, RR ;
ROSEN, BR ;
WISMER, GL ;
BRADY, TJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (01) :7-16
[4]   CLINICAL USE OF RAPID T2 WEIGHTED PARTIAL SATURATION SEQUENCES IN MR IMAGING [J].
BYDDER, GM ;
PAYNE, JA ;
COLLINS, AG ;
THOMAS, DGT ;
DAVIS, CH ;
COX, IJ ;
ROSS, BD ;
YOUNG, IR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (01) :17-23
[5]   SIGNAL-TO-NOISE RATIO AND SECTION THICKNESS IN TWO-DIMENSIONAL VERSUS 3-DIMENSIONAL FOURIER-TRANSFORM MR IMAGING [J].
CARLSON, J ;
CROOKS, L ;
ORTENDAHL, D ;
KRAMER, DM ;
KAUFMAN, L .
RADIOLOGY, 1988, 166 (01) :266-270
[6]   STEADY-STATE FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE [J].
CARR, HY .
PHYSICAL REVIEW, 1958, 112 (05) :1693-1701
[7]   ELIMINATION OF TRANSVERSE COHERENCES IN FLASH MRI [J].
CRAWLEY, AP ;
WOOD, ML ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1988, 8 (03) :248-260
[8]   PROJECTION ARTERIOGRAPHY AND VENOGRAPHY - INITIAL CLINICAL-RESULTS WITH MR [J].
EDELMAN, RR ;
WENTZ, KU ;
MATTLE, H ;
ZHAO, B ;
LIU, C ;
KIM, D ;
LAUB, G .
RADIOLOGY, 1989, 172 (02) :351-357
[9]  
EDELMAN RR, 1986, AM J NEURORADIOL, V7, P751
[10]   HALVING MR IMAGING TIME BY CONJUGATION - DEMONSTRATION AT 3.5 KG [J].
FEINBERG, DA ;
HALE, JD ;
WATTS, JC ;
KAUFMAN, L ;
MARK, A .
RADIOLOGY, 1986, 161 (02) :527-531