JPCALC, A SOFTWARE PACKAGE FOR CALCULATING LIQUID-JUNCTION POTENTIAL CORRECTIONS IN PATCH-CLAMP, INTRACELLULAR, EPITHELIAL AND BILAYER MEASUREMENTS AND FOR CORRECTING JUNCTION POTENTIAL MEASUREMENTS

被引:541
作者
BARRY, PH
机构
[1] School of Physiology and Pharmacology, University of New South Wales, Sydney
关键词
COMPUTER SOFTWARE; JUNCTION POTENTIAL; PATCH CLAMP; SINGLE CHANNEL; ELECTROPHYSIOLOGY; BILAYER; MICROCOMPUTER;
D O I
10.1016/0165-0270(94)90031-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The JPCalc program has been designed to graphically illustrate how junction potential contributions arise in various electrophysiological situations, to enable the magnitude and direction of those values to be readily calculated and to show clearly how the resultant appropriate corrections need to be applied to experimental measurements. In particular, the program covers the analysis of junction potential contributions and corrections in all the various different patch-clamp configurations (intact patches, inside-out patches, outside-out patches, whole-cell recording and perforated patches), intracellular recording, epithelial and bilayer measurements. It can also be used to correct experimental measurements designed to try to directly measure junction potentials and to compare both the magnitude and direction of such corrected measurements with their theoretical values. Although it is recommended that all of the above measurements be done with salt-filled electrodes or salt bridges, the program will allow the use of Ag/AgCl reference electrodes in direct contact with bathing solution in most situations. JPCalc also makes use of a library file of mobility and valency data for about 30 ions which can be extended by the user. In addition to its value in correcting electrical measurements, the program with its graphical displays may also be of value in focusing discussion about the contribution of junction potentials to such measurements and in helping to design experiments to either minimize their contribution or to measure their values. The JPCalc program, designed for IBM-compatible computers with color or monochrome monitors, can also be run on Macintosh computers with SoftPC emulation software.1
引用
收藏
页码:107 / 116
页数:10
相关论文
共 12 条
  • [1] Amman D., 1986, ION SELECTIVE MICROE
  • [2] LIQUID JUNCTION POTENTIALS AND SMALL-CELL EFFECTS IN PATCH-CLAMP ANALYSIS
    BARRY, PH
    LYNCH, JW
    [J]. JOURNAL OF MEMBRANE BIOLOGY, 1991, 121 (02) : 101 - 117
  • [3] BARRY PH, 1970, J MEMBRANE BIOL, V3, P93, DOI [10.1007/BF01868022, 10.1007/BF01868023]
  • [4] BARRY PH, 1989, METHOD ENZYMOL, V171, P678
  • [5] IMPROVED PATCH-CLAMP TECHNIQUES FOR HIGH-RESOLUTION CURRENT RECORDING FROM CELLS AND CELL-FREE MEMBRANE PATCHES
    HAMILL, OP
    MARTY, A
    NEHER, E
    SAKMANN, B
    SIGWORTH, FJ
    [J]. PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1981, 391 (02): : 85 - 100
  • [6] MACINNES DA, 1961, PRINCILES ELECTROCHE
  • [7] Marty A., 1983, SINGLE CHANNEL RECOR, P107
  • [8] Morf W.E., 1981, PRINCIPLES ION SELEC
  • [9] SINGLE-CHANNEL CURRENTS RECORDED FROM MEMBRANE OF DENERVATED FROG MUSCLE-FIBERS
    NEHER, E
    SAKMANN, B
    [J]. NATURE, 1976, 260 (5554) : 799 - 802
  • [10] NEHER E, 1994, IN PRESS SINGLE CHAN