H-POINT STANDARD ADDITIONS METHOD FOR ANALYTE DETERMINATION IN TERNARY MIXTURES

被引:20
作者
ANDRES, JV [1 ]
REIG, FB [1 ]
FALCO, PC [1 ]
机构
[1] UNIV VALENCIA, FAC QUIM, DEPT QUIM ANALIT, E-46100 BURJASSOT, SPAIN
关键词
TERNARY MIXTURE; H-POINT STANDARD ADDITIONS METHOD; ANALYTE DETERMINATION; BIAS ERROR; SPECTROPHOTOMETRY;
D O I
10.1039/an9952000299
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of the II-point standard additions method for resolving ternary mixtures is proposed, The method calculates the analyte concentration from spectral data at two wavelengths where the two species selected as interferents present the same absorbance relationship. These wavelength pairs are easily found, and can be selected to give the most precise results. If a matrix effect is present, use of the standard additions method is necessary in order to obtain good results, If there is no matrix effect, only sample absorbances and molar absorption coefficients are necessary, Ternary mixtures of phenol, o-cresol, 4-chlorophenol and 3,4-dichlorophenol, which are species with highly overlapped spectra throughout the wavelength range, were selected to test the method, The results obtained-are comparable to those obtained using multilinear regression.
引用
收藏
页码:299 / 304
页数:6
相关论文
共 13 条
[1]   MULTICOMPONENT ANALYSIS - COMPARISON OF VARIOUS GRAPHICAL AND NUMERICAL-METHODS [J].
BAUTISTA, RD ;
JIMENEZ, F ;
JIMENEZ, AI ;
ARIAS, JJ .
TALANTA, 1993, 40 (11) :1687-1694
[2]   DIODE-ARRAY DETECTORS IN FLOW-INJECTION ANALYSIS - MIXTURE RESOLUTION BY MULTI-WAVELENGTH ANALYSIS [J].
BLANCO, M ;
GENE, J ;
ITURRIAGA, H ;
MASPOCH, S ;
RIBA, J .
TALANTA, 1987, 34 (12) :987-993
[3]  
Draper N.R, 1998, APPL REGRESSION ANAL, V326, DOI 10.1002/9781118625590
[4]   APPARENT CONTENT CURVES - DESCRIPTION AND ANALYTICAL APPLICATIONS - RESOLUTION OF BINARY-MIXTURES [J].
ESTELLES, ML ;
SAEZ, RM ;
CIGES, MDSM .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (07) :538-546
[5]   SPECTROPHOTOMETRIC ANALYSIS OF MIXTURES OF 2 COMPONENTS WITH EXTENSIVELY OR COMPLETELY OVERLAPPING SPECTRA BY THE H-POINT STANDARD ADDITIONS METHOD [J].
FALCO, PC ;
REIG, FB ;
BENET, AM .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 338 (01) :16-21
[6]   APPLICATION OF THE H-POINT STANDARD ADDITIONS METHOD BY USING ABSORBENCY INCREMENT VALUES AS ANALYTICAL SIGNALS [J].
FALCO, PC ;
REIG, FB ;
VERDUANDRES, J .
TALANTA, 1992, 39 (01) :1-7
[7]  
FRAGA JMG, 1991, ANAL CHIM ACTA, V252, P107
[8]  
MARTENS H, 1985, THESIS U TRONDHEIM N
[9]  
Massart D. L., 1988, CHEMOMETRICS TXB
[10]   DERIVATIVE AND WAVELENGTH MODULATION SPECTROMETRY [J].
OHAVER, TC .