TRANSPARENT POLYURETHANE FILM AS AN INTRAVENOUS CATHETER DRESSING - A METAANALYSIS OF THE INFECTION RISKS

被引:160
作者
HOFFMANN, KK
WEBER, DJ
SAMSA, GP
RUTALA, WA
机构
[1] UNIV N CAROLINA HOSP,DEPT HOSP EPIDEMIOL,CHAPEL HILL,NC
[2] DUKE UNIV,DEPT COMMUNITY & FAMILY MED,DIV BIOMETRY & MED INFORMAT,DURHAM,NC 27706
来源
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION | 1992年 / 267卷 / 15期
关键词
D O I
10.1001/jama.267.15.2072
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective. - To obtain a quantitative estimate of the impact on infectious complications of using transparent dressings with intravenous catheters. Data Sources. - Meta-analysis of all studies published in the English literature, including abstracts, letters, and reports that examined the primary research question of infection risks associated with transparent compared with gauze dressings for use on central and peripheral venous catheters. Studies were identified by use of the MEDLINE database using the indexing terms occlusive dressings, transparent dressings, and infection and by review of referenced bibliographies. Study Selection. - Seven of the 15 studies (47%) of central venous catheters and seven of 12 studies (58%) of peripheral catheters met our inclusion criteria for analysis. All studies used a prospective cohort design, utilized hospitalized patients, and reported at least one of our defined outcomes. Extraction. - Data for each study were abstracted independently by three investigators. At least three studies were used in the analysis of each outcome. Data Synthesis. - Applying a Mantel-Haenszel chi-2 analysis, use of transparent dressings on central venous catheters was significantly associated with an elevated relative risk (RR) of catheter tip infection (RR = 1.78; 95% confidence interval [Cl], 1.38 to 2.30). Catheter-related sepsis (RR = 1.69; 95% Cl, 0.97 to 2.95) and bacteremia (RR = 1.63; 95% Cl, 0.76 to 3.47) were both associated with an elevated RR. Use of transparent dressings on peripheral catheters was associated with an elevated RR of catheter-tip infection (RR = 1.53; 95% Cl, 1.18 to 1.99) but not phlebitis(RR = 1.02; 95% Cl, 0.86 to 1.20), infiltration (RR = 1.12; 95% Cl, 0.92 to 1.37), or skin colonization (RR = 0.99; 95% Cl, 0.90 to 1.09). Conclusion. - The results demonstrated a significantly increased risk of catheter-tip infection with the use of transparent compared with gauze dressings when used with either central or peripheral catheters. An increased risk of bacteremia and catheter sepsis associated with the use of transparent compared with gauze dressings for use on central venous catheters was suggested.
引用
收藏
页码:2072 / 2076
页数:5
相关论文
共 40 条
  • [1] EFFECT OF PROLONGED OCCLUSION ON THE MICROBIAL-FLORA, PH, CARBON-DIOXIDE AND TRANS-EPIDERMAL WATER-LOSS ON HUMAN-SKIN
    ALY, R
    SHIRLEY, C
    CUNICO, B
    MAIBACH, HI
    [J]. JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1978, 71 (06) : 378 - 381
  • [2] A COMPARATIVE-STUDY OF OP-SITE AND NOBECUTAN GAUZE DRESSINGS FOR CENTRAL VENOUS LINE CARE
    ANDERSEN, PT
    HERLEVSEN, P
    SCHAUMBURG, H
    [J]. JOURNAL OF HOSPITAL INFECTION, 1986, 7 (02) : 161 - 168
  • [3] BERRY R, 1986, MAY NAT INTR THER AS
  • [4] BULPITT CJ, 1988, LANCET, V2, P93
  • [5] A PROSPECTIVE, RANDOMIZED STUDY COMPARING TRANSPARENT AND DRY GAUZE DRESSINGS FOR CENTRAL VENOUS CATHETERS
    CONLY, JM
    GRIEVES, K
    PETERS, B
    [J]. JOURNAL OF INFECTIOUS DISEASES, 1989, 159 (02) : 310 - 319
  • [6] A RANDOMIZED STUDY COMPARING A TRANSPARENT POLYURETHANE DRESSING TO A DRY GAUZE DRESSING FOR PERIPHERAL INTRAVENOUS CATHETER SITES
    CRAVEN, DE
    LICHTENBERG, DA
    KUNCHES, LM
    MCDONOUGH, AT
    GONZALEZ, MI
    HEEREN, TC
    MCCABE, WR
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 1985, 6 (09) : 361 - 366
  • [7] CLINICALLY SIGNIFICANT CENTRAL VENOUS CATHETER INFECTIONS IN A COMMUNITY-HOSPITAL - ASSOCIATION WITH TYPE OF DRESSING
    DICKERSON, N
    HORTON, P
    SMITH, S
    ROSE, RC
    [J]. JOURNAL OF INFECTIOUS DISEASES, 1989, 160 (04) : 720 - 721
  • [8] DOWNING JW, 1987, S AFR MED J, V72, P191
  • [9] PUBLICATION BIAS IN CLINICAL RESEARCH
    EASTERBROOK, PJ
    BERLIN, JA
    GOPALAN, R
    MATTHEWS, DR
    [J]. LANCET, 1991, 337 (8746) : 867 - 872
  • [10] A METHOD FOR META-ANALYSIS OF EPIDEMIOLOGICAL-STUDIES
    EINARSON, TR
    LEEDER, JS
    KOREN, G
    [J]. DRUG INTELLIGENCE & CLINICAL PHARMACY, 1988, 22 (10): : 813 - 824