ION CHROMATOGRAPHY MASS-SPECTROMETRY FOR THE DETERMINATION OF ORGANIC AMMONIUM AND SULFATE COMPOUNDS

被引:118
作者
CONBOY, JJ
HENION, JD
MARTIN, MW
ZWEIGENBAUM, JA
机构
[1] CORNELL UNIV,925 WARREN DR,ITHACA,NY 14853
[2] EASTMAN KODAK CO,DIV ANALYT TECHNOL,ROCHESTER,NY 14652
关键词
D O I
10.1021/ac00207a006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The ion spray liquid chromatography/mass spectrometry (LC/MS) Interface Is coupled via a postsuppressor split with an ion chromatography (IC) system. The micromembrane suppressor selectively removes over 99.9 % of the ion-pair agents required for ion chromatography from the eluent. The resulting solution consists of analyte, organic modifier, and water, which is compatible with Ion evaporation mass spectrometry. A flow rate of 0.8 or 1.0 mL/min from the column was split after suppression such that approximately 10–20 μL/min was directed to the ion spray LC/MS interface, which was coupled to an atmospheric pressure ionization (API) mass spectrometer. This system provided a convenient way to effect lsocratic and gradient separations of organic ions under chromatographic conditions incompatible with most forms of mass spectrometric ionization. This work describes the separation and positive ion detection of quaternary ammonium drugs and tetraalkylammonlum compounds of industrial importance using both single and tandem mass spectrometric detection (e.g., IC/MS and IC/MS/MS). The former easily provided the molecular weights of these compounds while the latter gave some structural information. The limit of detection (LOD) of 40 pg Injected on-column for tetrapropylammonlum cation Is a factor of 10 better than that obtained with the conventional IC conductivity detector. The separation, detection, and Identification of some alkyl sulfates and sulfonates are also shown with negative Ion detection. Again, IC/MS readily produced the molecular weights of these compounds while IC/MS/MS provided some structural information. © 1990, American Chemical Society. All rights reserved.
引用
收藏
页码:800 / 807
页数:8
相关论文
共 24 条
  • [1] ALOMAIR AS, 1988, 36TH ASMS C MASS SPE
  • [2] DETERMINATION OF ORGANIC-ANIONS BY ION CHROMATOGRAPHY USING A HOLLOW FIBER SUPPRESSOR
    BOUYOUCOS, SA
    [J]. JOURNAL OF CHROMATOGRAPHY, 1982, 242 (01): : 170 - 176
  • [3] ION SPRAY INTERFACE FOR COMBINED LIQUID CHROMATOGRAPHY/ATMOSPHERIC PRESSURE IONIZATION MASS-SPECTROMETRY
    BRUINS, AP
    COVEY, TR
    HENION, JD
    [J]. ANALYTICAL CHEMISTRY, 1987, 59 (22) : 2642 - 2646
  • [4] COVEY TR, 1986, ANAL CHEM, V58, P1451
  • [5] ION PENETRATION THROUGH TUBULAR ION-EXCHANGE MEMBRANES
    DASGUPTA, PK
    BLIGH, RQ
    LEE, J
    DAGOSTINO, V
    [J]. ANALYTICAL CHEMISTRY, 1985, 57 (01) : 253 - 257
  • [6] ION CHROMATOGRAPHY WITH AN ION-EXCHANGE MEMBRANE SUPPRESSOR
    HANAOKA, Y
    MURAYAMA, T
    MURAMOTO, S
    MATSUURA, T
    NANBA, A
    [J]. JOURNAL OF CHROMATOGRAPHY, 1982, 239 (APR): : 537 - 548
  • [7] AMPEROMETRIC DETECTION OF SIMPLE CARBOHYDRATES AT PLATINUM-ELECTRODES IN ALKALINE-SOLUTIONS BY APPLICATION OF A TRIPLE-PULSE POTENTIAL WAVEFORM
    HUGHES, S
    JOHNSON, DC
    [J]. ANALYTICA CHIMICA ACTA, 1981, 132 (DEC) : 11 - 22
  • [8] AMPEROMETRIC DETECTION OF SIMPLE ALCOHOLS IN AQUEOUS-SOLUTIONS BY APPLICATION OF A TRIPLE-PULSE POTENTIAL WAVEFORM AT PLATINUM-ELECTRODES
    HUGHES, S
    MESCHI, PL
    JOHNSON, DC
    [J]. ANALYTICA CHIMICA ACTA, 1981, 132 (DEC) : 1 - 10
  • [9] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION WITH TRIPLE-PULSE AMPEROMETRIC DETECTION OF CARBOHYDRATES IN BEVERAGES
    HUGHES, S
    JOHNSON, DC
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1982, 30 (04) : 712 - 714
  • [10] ATMOSPHERIC-PRESSURE ION EVAPORATION MASS-SPECTROMETRY
    IRIBARNE, JV
    DZIEDZIC, PJ
    THOMSON, BA
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1983, 50 (03): : 331 - 347