SEMIAUTOMATIC TRACKING OF MYOCARDIAL MOTION IN MR TAGGED IMAGES

被引:59
作者
KRAITCHMAN, DL
YOUNG, AA
CHANG, CN
AXEL, L
机构
[1] Pendergrass Radiology Research Laboratory, Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia
基金
美国国家卫生研究院;
关键词
D O I
10.1109/42.414606
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Tissue tagging using magnetic resonance (MR) imaging has enabled quantitative noninvasive analysis of motion and deformation in vivo. One method for MR tissue tagging is Spatial Modulation of Magnetization (SPAMM), Manual detection and tracking of tissue tags by visual inspection remains a time-consuming and tedious process. We have developed an interactively guided semi-automated method of detecting and tracking tag intersections in cardiac MR images, A template matching approach combined with a novel adaptation of active contour modeling permits rapid analysis of MR images. We have validated our technique using MR SPAMM images of a silicone gel phantom with controlled deformations. Average discrepancy between theoretically predicted and semi-automatically selected tag intersections was 0.30 mm +/- 0.17 [mean +/- SD, NS (P < 0.05)]. Cardiac SPAMM images of normal volunteers and diseased patients also have been evaluated using our technique.
引用
收藏
页码:422 / 433
页数:12
相关论文
共 23 条
  • [1] SOME GENERAL RESULTS IN THE THEORY OF LARGE ELASTIC DEFORMATIONS
    ADKINS, JE
    [J]. PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1955, 231 (1184): : 75 - 90
  • [2] AMINI AA, 1994, AAAI INT S COMP VISI
  • [3] REGIONAL HEART WALL MOTION - 2-DIMENSIONAL ANALYSIS AND FUNCTIONAL IMAGING WITH MR IMAGING
    AXEL, L
    GONCALVES, RC
    BLOOMGARDEN, D
    [J]. RADIOLOGY, 1992, 183 (03) : 745 - 750
  • [4] HEART WALL MOTION - IMPROVED METHOD OF SPATIAL MODULATION OF MAGNETIZATION FOR MR IMAGING
    AXEL, L
    DOUGHERTY, L
    [J]. RADIOLOGY, 1989, 172 (02) : 349 - 350
  • [5] INHOMOGENEOUS DEFORMATION AS A SOURCE OF ERROR IN STRAIN-MEASUREMENTS DERIVED FROM IMPLANTED MARKERS IN THE CANINE LEFT-VENTRICLE
    DOUGLAS, AS
    HUNTER, WC
    WISEMAN, MD
    [J]. JOURNAL OF BIOMECHANICS, 1990, 23 (04) : 331 - 341
  • [6] FISHER D, 1990, THESIS U IOWA IOWA C
  • [7] A SILICONE GEL PHANTOM SUITABLE FOR MULTIMODALITY IMAGING
    GOLDSTEIN, DC
    KUNDEL, HL
    DAUBEWITHERSPOON, ME
    THIBAULT, LE
    GOLDSTEIN, EJ
    [J]. INVESTIGATIVE RADIOLOGY, 1987, 22 (02) : 153 - 157
  • [8] GREEN AE, 1968, THEORETICAL ELASTICI, P99
  • [9] TAG AND CONTOUR-DETECTION IN TAGGED MR-IMAGES OF THE LEFT-VENTRICLE
    GUTTMAN, MA
    PRINCE, JL
    MCVEIGH, ER
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (01) : 74 - 88
  • [10] IBRAHIM YM, 1993, P IEEE ENG MED BIOL, P168