IN-VIVO MEASUREMENTS OF THE PHASE CONSTANTS OF TRANSVERSE MECHANICAL WAVES IN A HUMAN TIBIA FROM 100-HZ TO 1000-HZ

被引:3
作者
COLLIER, RJ
NTUI, JA
机构
[1] The Electronic Engineering Laboratories, The University of Kent, Canterbury, Kent
关键词
PHASE CONSTANTS; TRANSVERSE MECHANICAL WAVES; TIBIA;
D O I
10.1016/1350-4533(90)90004-R
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper contains the details of a new technique for measuring the mechanical phase constants of transverse waves in human tibia, in vivo. The measurements are made in the frequency range from 100 to 1000 Hz. The importance other hand, a fractured tibia has a large phase delay at the fracture site. This paper establishes a set of typical phase delays for a range of tibia so that subsequent measurements on fractured patients can be interpreted. It contains a description of the method of measuring the phase delay and a detailed analysis of errors. In particular, it includes an account of the phase delay through the soft tissues as well as the bone and how the former can be eliminated. It is not an exhaustive account of this topic but contains sufficient results to show that the measurements can be made relatively easily. Finally, there is a theoretical model which can be used to predict the phase shift. However, in order to use the model various other measurements are necessary and a direct measurement of phase is easier than using a model.
引用
收藏
页码:379 / 383
页数:5
相关论文
共 5 条
[1]   NONINVASIVE METHOD OF MEASURING RESONANT-FREQUENCY OF A HUMAN TIBIA INVIVO .1. [J].
COLLIER, RJ ;
DONARSKI, RJ .
JOURNAL OF BIOMEDICAL ENGINEERING, 1987, 9 (04) :321-328
[2]  
COLLIER RJ, 1993, OXFORD MED ENG SERIE, V10, pCH18
[3]  
DONARSKI RJ, 1989, THESIS U KENT CANTER
[4]  
Graff K. F., 1975, WAVE MOTION ELASTIC
[5]  
VANDERPERRE G, 1985, MONITORING FRACTURE