MTT COLORIMETRIC ASSAY DETECTS MITOGEN RESPONSES OF SPLEEN BUT NOT BLOOD-LYMPHOCYTES

被引:21
作者
CHEN, CH
CAMPBELL, PA
NEWMAN, LS
机构
[1] NATL JEWISH CTR IMMUNOL & RESPIRAT MED,DEPT MED,1400 JACKSON ST,DENVER,CO 80206
[2] UNIV COLORADO,SCH MED,DEPT MED,DENVER,CO 80202
[3] UNIV COLORADO,SCH MED,DEPT PATHOL,DENVER,CO 80202
[4] UNIV COLORADO,SCH MED,DEPT MICROBIOL & IMMUNOL,DENVER,CO 80202
来源
INTERNATIONAL ARCHIVES OF ALLERGY AND APPLIED IMMUNOLOGY | 1990年 / 93卷 / 2-3期
关键词
D O I
10.1159/000235309
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
In an effort to simplify methods for assessing mitogen stimulation of blood lymphocytes, the MTT (3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyl tetrazolium bromide) colorimetric assay [1] was compared with the conventional tritiated thymidine deoxyriboside (H-3-TdR) incorporation assay. Although able to detect mitogen responses by mouse and rat spleen cells, the MTT assay did not reliably measure blood mononuclear cell responses in mouse, rat or man. The H-3-TdR incorporation assay was effective in every case. Modifications of the MTT assay procedure did not rectify this disparity, which was caused in part by high MTT optical density readings by unstimulated cells. The inability of the MTT assay to detect mitogen responses by blood cells seems to reflect a species-independent physiologic property of these cells.
引用
收藏
页码:249 / 255
页数:7
相关论文