A SIMPLE, RAPID AND SIMULTANEOUS ANALYSIS OF COMPLEX VOLATILE HYDROCARBON MIXTURES IN BLOOD USING GAS-CHROMATOGRAPHY MASS-SPECTROMETRY WITH A WIDE-BORE CAPILLARY COLUMN

被引:9
作者
MORINAGA, M [1 ]
HARA, K [1 ]
KAGEURA, M [1 ]
HIEDA, Y [1 ]
TAKAMOTO, M [1 ]
KASHIMURA, S [1 ]
机构
[1] FUKUOKA UNIV,SCH MED,DEPT LEGAL MED,7-45-1 NANAKUMA,JONAN KU,FUKUOKA 81401,JAPAN
来源
ZEITSCHRIFT FUR RECHTSMEDIZIN-JOURNAL OF LEGAL MEDICINE | 1990年 / 103卷 / 08期
关键词
screening method; Volatile hydrocarbons in the blood;
D O I
10.1007/BF01261420
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
A screening method for detecting volatile hydrocarbons in blood has been developed using gas chromatography/mass spectrometry with a wide-bore capillary column and a headspace method. Toluene-d8 and indan were used as the internal standards for quantitative analysis. Hydrocarbons with retention indices from 600 to 1200 were simultaneously and quantitatively detected in relatively low concentrations (0.01 μg/m1) in reconstructed ion chromatography. This method could prove useful in forensic cases in which urgent examination of complex hydrocarbon mixtures, e.g. petroleum components, is required. © 1990 Springer-Verlag.
引用
收藏
页码:567 / 572
页数:6
相关论文
共 11 条
  • [1] TRACE ANALYSIS OF METHANOL IN RAT SERUM BY HEADSPACE HIGH-RESOLUTION GAS-CHROMATOGRAPHY SELECTED ION MONITORING
    DAVOLI, E
    CAPPELLINI, L
    AIROLDI, L
    FANELLI, R
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1986, 24 (03) : 113 - 116
  • [2] GASOLINE AND KEROSENE COMPONENTS IN BLOOD - A FORENSIC ANALYSIS
    KIMURA, K
    NAGATA, T
    HARA, K
    KAGEURA, M
    [J]. HUMAN TOXICOLOGY, 1988, 7 (04): : 299 - 305
  • [3] AN ADSORPTION SAMPLING METHOD COMBINED WITH CAPILLARY COLUMN GAS-CHROMATOGRAPHY AND CRYOGENIC FOCUSING FOR TRACE ANALYSIS OF VOLATILE ORGANIC-COMPOUNDS
    KOBUS, HJ
    KIRKBRIDE, KP
    MAEHLY, A
    [J]. JOURNAL OF THE FORENSIC SCIENCE SOCIETY, 1987, 27 (05): : 307 - 314
  • [4] VOLATILE ENVIRONMENTAL-POLLUTANTS IN BIOLOGICAL MATRICES WITH A HEADSPACE PURGE TECHNIQUE
    MICHAEL, LC
    ERICKSON, MD
    PARKS, SP
    PELLIZZARI, ED
    [J]. ANALYTICAL CHEMISTRY, 1980, 52 (12) : 1836 - 1841
  • [5] NAGATA T, 1977, JPN J LEGAL MED, V31, P136
  • [6] NAGATA T, 1983, 2ND P SCAND C FOR SC, P77
  • [7] RETENTION INDEXES AND DUAL CAPILLARY GAS-CHROMATOGRAPHY FOR RAPID IDENTIFICATION OF SEDATIVE HYPNOTIC DRUGS IN EMERGENCY TOXICOLOGY
    NEWTON, B
    FOERY, RF
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 1984, 8 (03) : 129 - 134
  • [8] PENTON Z, 1987, CLIN CHEM, V33, P2094
  • [9] ASSAY OF METHYL-METHACRYLATE IN BLOOD-SAMPLES BY HEADSPACE CAPILLARY GAS-CHROMATOGRAPHY
    PFAFFLI, P
    SVARTLING, N
    [J]. JOURNAL OF CHROMATOGRAPHY, 1985, 345 (02): : 386 - 389
  • [10] ANALYSIS OF C1-C3 ALCOHOLS IN BLOOD BY HIGH-RESOLUTION HEADSPACE GAS-CHROMATOGRAPHY
    TERMONIA, M
    DEMEYER, A
    WYBAUW, M
    JACOBS, H
    [J]. JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1982, 5 (07): : 377 - 378