QUALITY ASSURANCE OF THE EORTC TRIAL 22881/10882 - ASSESSMENT OF THE ROLE OF THE BOOSTER DOSE IN BREAST CONSERVING THERAPY - THE DUMMY RUN

被引:49
作者
VANTIENHOVEN, G [1 ]
VANBREE, NAM [1 ]
MIJNHEER, BJ [1 ]
BARTELINK, H [1 ]
机构
[1] ANTONI VAN LEEUWENHOEK HOSP,NETHERLANDS CANC INST,DEPT RADIOTHERAPY,AMSTERDAM,NETHERLANDS
关键词
BREAST NEOPLASM; BREAST CONSERVING THERAPY; CLINICAL TRIAL; QUALITY ASSURANCE; TANGENTIAL BREAST IRRADIATION; DOSE DISTRIBUTION;
D O I
10.1016/0167-8140(91)90165-D
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The EORTC trial 22881/10882 is a randomised trial with the aim to assess the role of the boost dose in breast conserving therapy in stage I and II breast cancer. In order to detect potential protocol deviations concerning irradiation technique and in the dose specification procedure of participating institutions before actual patient accrual, a Dummy Run was performed. Three transverse sections of a patient were sent to 16 participating institutions with a request to make a three-plane treatment plan according to the protocol prescriptions. A treatment chart and beam data were also requested for recalculation of the dose. Additional information was asked in a questionnaire. On evaluation, the techniques differed considerably with respect to photon beam energy, varying between Co-60 gamma-rays and 8 MV X-rays, and the use of wedge filters. Two institutions did not apply wedges, whereas wedge angles in the other institutions varied between 6-degrees and 45-degrees. Twelve institutions used collimator rotation and/or a table wedge to diminish the amount of irradiated lung volume. The dose was specified in a point according to the protocol prescription in 11 institutions and to the 90, 95 or 100% isodose curve in four. Twelve institutions applied lung density corrections during treatment planning, while nine reported problems with their planning system in off-axis dose distribution calculation and/or the simulation of collimator rotation. Recalculation of the dose at the isocentre showed agreement within 2% compared with the stated dose. The dose reported in the tumour excision area varied between 93 and 100%. It can be concluded that good accordance and high quality breast irradiation can be achieved by all institutions participating in the trial, provided a few recommendations are followed. The results of this analysis show the necessity and usefulness of a quality assurance programme at the initial phase of a clinical trial.
引用
收藏
页码:290 / 298
页数:9
相关论文
共 28 条
[1]   CAN SIMULATION MEASUREMENTS BE USED TO PREDICT THE IRRADIATED LUNG-VOLUME IN THE TANGENTIAL FIELDS IN PATIENTS TREATED FOR BREAST-CANCER [J].
BORNSTEIN, BA ;
CHENG, CW ;
RHODES, LM ;
RASHID, H ;
STOMPER, PC ;
SIDDON, RL ;
HARRIS, JR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (01) :181-187
[2]   3-DIMENSIONAL PHOTON DOSE DISTRIBUTIONS WITH AND WITHOUT LUNG CORRECTIONS FOR TANGENTIAL BREAST INTACT TREATMENTS [J].
CHIN, LM ;
CHENG, CW ;
SIDDON, RL ;
RICE, RK ;
MIJNHEER, BJ ;
HARRIS, JR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 17 (06) :1327-1335
[3]  
CHIN LM, 1987, USE COMPUTERS RAD TH, P169
[4]   A NONDIVERGENT 3 FIELD MATCHING TECHNIQUE FOR BREAST IRRADIATION [J].
CHU, JCH ;
SOLIN, LJ ;
HWANG, CC ;
FOWBLE, B ;
HANKS, GE ;
GOODMAN, RL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 19 (04) :1037-1040
[5]   THE INFLUENCE OF LUNG DENSITY CORRECTIONS ON TREATMENT PLANNING FOR PRIMARY BREAST-CANCER [J].
FRAASS, BA ;
LICHTER, AS ;
MCSHAN, DL ;
YANKE, BR ;
DIAZ, RF ;
YEAKEL, KS ;
VANDEGEIJN, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (01) :179-190
[6]   IMPROVED DOSE DISTRIBUTION HOMOGENEITY IN CONSERVATIVE BREAST-CANCER IRRADIATION [J].
GARAVAGLIA, G ;
POREPP, C ;
JOZEFOWSKY, M .
RADIOTHERAPY AND ONCOLOGY, 1991, 22 (04) :245-247
[7]   ENTRANCE AND EXIT TL-DOSIMETRY IN THE CONSERVATIVE TREATMENT OF BREAST-CANCER - A PILOT-STUDY FOR THE EORTC-RADIOTHERAPY COOPERATIVE GROUP [J].
HAMERS, HP ;
JOHANSSON, KA ;
VENSELAAR, JLM ;
DEBROUWER, P ;
HANSSON, U ;
MOUDI, C .
RADIOTHERAPY AND ONCOLOGY, 1991, 22 (04) :280-284
[8]   QUALITY AUDIT OF RADIOTHERAPY WITH EORTC MAILED IN WATER TL-DOSIMETRY [J].
HANSSON, U ;
JOHANSSON, KA .
RADIOTHERAPY AND ONCOLOGY, 1991, 20 (03) :191-196
[9]   TECHNIQUE FOR BREAST IRRADIATION USING CUSTOM BLOCKS CONFORMING TO THE CHEST-WALL CONTOUR [J].
HARTSELL, WF ;
MURTHY, AK ;
KIEL, KD ;
KAO, M ;
HENDRICKSON, FR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 19 (01) :189-195
[10]   INVIVO DOSIMETRY DURING TANGENTIAL BREAST TREATMENT [J].
HEUKELOM, S ;
LANSON, JH ;
VANTIENHOVEN, G ;
MIJNHEER, BJ .
RADIOTHERAPY AND ONCOLOGY, 1991, 22 (04) :269-279