A METHOD FOR CALCULATION OF MARGINS TO VOLTAGE INSTABILITY APPLIED ON THE NORWEGIAN SYSTEM FOR MAINTAINING REQUIRED SECURITY LEVEL

被引:36
作者
FLATABO, N
FOSSO, OB
OGNEDAL, R
CARLSEN, T
HEGGLAND, KR
机构
[1] The Norwegian Electric Power, Research Institute (EFI), Norway
关键词
REACTIVE POWER MARGINS; VOLTAGE COLLAPSE; SENSITIVITY METHODS;
D O I
10.1109/59.260910
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper describes a method for calculating margins to voltage instability. The method is based on sensitivity techniques. The measure to voltage instability can be given in terms of MW, MVAr or MVA depending on the components in the increase in load. The extensions to earlier publications of the method are the ability to increase the load and generation simultaneously on several buses without increasing the computation time. A single forward and backward substitution is sufficient to find the required sensitivities when the load is increased. The productions of the plant can be increased either by a specified profile or by using the turbine droop characteristics. A method for identification of contingencies needing an explicit reserve evaluation is briefly described.
引用
收藏
页码:920 / 928
页数:9
相关论文
共 8 条
[1]  
Christensen J. F., 1987, Electra, P55
[2]  
Flatabo N., 1990, IEEE T POWER SYSTEMS, V5
[3]  
LOF PA, FAST CALCULATION VOL
[4]  
OBADINA OO, 1988 IEEE PES WINT M
[5]  
PAL MK, 1991, FEB IEEE PES WINT M
[6]  
VANCUTSEM T, 1991, IEEE T POWER SYSTEMS, V6
[7]  
IEEE90TH03582 CAT
[8]  
1987, ELECTRA MAR, P55