A large volume negative ion source, which has a newly devised magnetic filter called a PG filter, was designed and tested. The PG filter produces a uniform magnetic filter field over a large extraction area of 14×36 cm2 by flowing a high current through the plasma grid itself. By optimizing the filter strength, we succeeded to produce 3.4-A 75-keV negative hydrogen ion beams for 50 ms from 253 apertures of 11.3 mm diam with an average current H- density of 13 mA/cm2.