AN IN-VIVO AUTOMATED SHIMMING METHOD TAKING INTO ACCOUNT SHIM CURRENT CONSTRAINTS

被引:39
作者
WEN, H [1 ]
JAFFER, FA [1 ]
机构
[1] NHLBI,CARDIAC ENERGET LAB,BETHESDA,MD 20892
关键词
COMPUTERIZED; SHIMMING; MAGNETIC FIELD;
D O I
10.1002/mrm.1910340616
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Many in vivo imaging techniques require magnetic field homogeneity in the volume of interest, Shim coils of the second and third order spherical harmonics have been used successfully to compensate for complicated field variations caused by the human anatomy itself, The available currents of these coils are invariably limited. In this note we demonstrate that these limits significantly affect the optimal shim condition, We propose an automated in vivo shimming method for arbitrary volumes of interest using 3-dimensional (3D) field maps, This method is a modification of previous works using least-squares criteria, The main difference is that a constrained optimization is performed in vivo under the current limits of the shim coils, which improved the field homogeneity significantly over simple truncations of the least-squares solutions, This shimming method was used with head scans of five normal volunteers on a 4.0 tesla scanner. A fast double-echo sequence was used to obtain field maps, and a new field uniformity measure was derived for this method, The field mapping sequence was tested against a standard single-echo Dixon sequence used by previous investigators, and the stability of the shimming method was tested by repeated studies on the same subject.
引用
收藏
页码:898 / 904
页数:7
相关论文
共 18 条
[1]   CORRECTION OF PHASE WRAPPING IN MAGNETIC-RESONANCE IMAGING [J].
AXEL, L ;
MORTON, D .
MEDICAL PHYSICS, 1989, 16 (02) :284-287
[2]  
BRUETTER R, 1992, J MAGN RESON, V96, P323
[3]   THE EFFECTS OF BONE ON PROTON NMR RELAXATION-TIMES OF SURROUNDING LIQUIDS [J].
DAVIS, CA ;
GENANT, HK ;
DUNHAM, JS .
INVESTIGATIVE RADIOLOGY, 1986, 21 (06) :472-477
[4]   SIMPLE PROTON SPECTROSCOPIC IMAGING [J].
DIXON, WT .
RADIOLOGY, 1984, 153 (01) :189-194
[5]   MEASUREMENTS OF MAGNETIC-FIELD VARIATIONS IN THE HUMAN BRAIN USING A 3D-FT MULTIPLE GRADIENT-ECHO TECHNIQUE [J].
ERICSSON, A ;
WEIS, J ;
HEMMINGSSON, A ;
WIKSTROM, M ;
SPERBER, GO .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (02) :171-177
[6]   SHIMMING ON SPATIALLY LOCALIZED SIGNALS [J].
HOULT, DI .
JOURNAL OF MAGNETIC RESONANCE, 1987, 73 (01) :174-177
[7]  
JAFFER FA, 1995, 3RD P SMR ANN M NIC, P1413
[8]   EDDY-CURRENT-COMPENSATED FIELD-INHOMOGENEITY MAPPING IN NMR IMAGING [J].
KIM, YS ;
CHO, ZH .
JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (03) :459-471
[9]   A SIMPLE FIELD MAP FOR SHIMMING [J].
MACKENZIE, IS ;
ROBINSON, EM ;
WELLS, AN ;
WOOD, B .
MAGNETIC RESONANCE IN MEDICINE, 1987, 5 (03) :262-268
[10]   MAGNETIC-FIELD MEASUREMENT BY NMR IMAGING [J].
MAUDSLEY, AA ;
SIMON, HE ;
HILAL, SK .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1984, 17 (03) :216-220