AORTIC COMPLIANCE MEASURED BY NONINVASIVE DOPPLER ULTRASOUND - DESCRIPTION OF A METHOD AND ITS REPRODUCIBILITY

被引:70
作者
WRIGHT, JS
CRUICKSHANK, JK
KONTIS, S
DORE, C
GOSLING, RG
机构
[1] NORTHWICK PK HOSP & CLIN RES CTR,CTR CLIN RES,DEPT MED,WATFORD RD,HARROW HA1 3UJ,MIDDX,ENGLAND
[2] NORTHWICK PK HOSP & CLIN RES CTR,CTR CLIN RES,MED STAT SECT,HARROW HA1 3UJ,MIDDX,ENGLAND
[3] UNITED MED & DENT SCH,DEPT RADIOL SCI,ULTRASOUND ANGIOL RES GRP,LONDON,ENGLAND
关键词
aortic compliance; Doppler method; reproducibility;
D O I
10.1042/cs0780463
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Aortic compliance (expressed as percentage increase in lumen diameter for a pulse pressure of 10 mmHg) was calculated from the characteristic pulse wave velocity deduced from 'foot to foot' transit times of the blood flow pulse over a measured length of aorta. Two continous wave Doppler ultrasound transducers were used: one insonating the root of the left subclavian artery, the other the abdominal aorta proximal to its bifurcation. Measurements were made after the subject had been supine for 5 min to achieve stable conditions. Transmit times were calculated on-line in real-time from the delay between the start of the systolic upstroke in the flow velocity sonograms recorded by the two transducers. Within-visit variation was minimized by measuring over 45 cardiac cycles repeated three separate times and calculating an overall mean value for aortic compliance. A full measurement took 5-10 min. Reproducibility of this overall mean value of aortic compliance was assessed at 1 month in 30 subjects (aged 60 ± 7 years, mean ± SD) and at 3 months in 23 different subjects (59 ± 8 years). Aortic compliance values ranged from 0.1 to 2.0%/10 mmHg. The mean paired difference between aortic compliance values was -0.02 between 0 and 1 month, and 0.03 between 0 and 3 months, with respective 95% confidence limits of -0.06 to 0.03 and -0.03 to 0.09 embracing zero, thus not differing significantly from baseline. Aortic compliance can be both simply and reproducibly measured non-invasely; if an individual was measured on two occassions, then 95% of the time the difference between the two measurements of aortic compliance would be <0.28 (twice the SD of the 3 month differences).
引用
收藏
页码:463 / 468
页数:6
相关论文
共 29 条