PEDIATRIC CRANIOFACIAL SURGERY - COMPARISON OF MILLING AND STEREOLITHOGRAPHY FOR 3D-MODEL MANUFACTURING

被引:77
作者
KLEIN, HM
SCHNEIDER, W
ALZEN, G
VOY, ED
GUNTHER, RW
机构
[1] UNIV TECHNOL AACHEN,MED CTR,DEPT DIAGNOST RADIOL,AACHEN,GERMANY
[2] EVANGEL KRANKENHAUS,DEPT MAXILLOFACIAL & PLAST SURG,HATTINGEN,GERMANY
关键词
D O I
10.1007/BF02013512
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
To improve the planning phase for pediatric craniofacial surgery, 3D reconstructions of CT image series were performed on a personal computer. For construction of true models of the surgical site, two concepts were pursued. CT image data of six patients were used for model manufacturing by a conventional 21/2 axis milling system. The material used was polyurethane foam. Alternatively, in one patient a stereolithography was produced on the basis of the 3D reconstructed CT data. This new manufacturing device uses a photocurable monomer, hardened by a UV-laser. The spatial resolution of the system is about 0.1 mm. 3D-reconstructions were performed on a personal computer. Data were then transferred into a surface oriented structure to control a stereolithographic modeling device. Time for transfer was 70 min. The production of the modelled cranium took a total time of 59 h. Accuracy was found to be much higher in stereolithography than in milled models. The model served for surgical planning. The long time for production was caused by inadequate computer capacities, which are configured for much less complex objects in computer aided design. Furthermore the programs for the machine control are optimized for technical purposes. If theses conditions are improved, stereolithography could be an attractive alternative to milling of medical models.
引用
收藏
页码:458 / 460
页数:3
相关论文
共 20 条
  • [1] LINEAR OCTTREES FOR FAST PROCESSING OF 3-DIMENSIONAL OBJECTS
    GARGANTINI, I
    [J]. COMPUTER GRAPHICS AND IMAGE PROCESSING, 1982, 20 (04): : 365 - 374
  • [2] 3-DIMENSIONAL DISPLAY OF HUMAN ORGANS FROM COMPUTED TOMOGRAMS
    HERMAN, GT
    LIU, HK
    [J]. COMPUTER GRAPHICS AND IMAGE PROCESSING, 1979, 9 (01): : 1 - 21
  • [3] HOHNE KH, 1990, NATO ADV SCI I F-COM, V60, P197
  • [4] SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION
    KALENDER, WA
    SEISSLER, W
    KLOTZ, E
    VOCK, P
    [J]. RADIOLOGY, 1990, 176 (01) : 181 - 183
  • [5] KLIEGIS U, 1989, P CAR, V747
  • [6] KULICK JH, 1988, SPIE MED IMAGING, V914, P1265
  • [7] LEHRIG R, 1989, SCHNELLE 3D VERARBEI, V1, P220
  • [8] RHODES ML, 1985, P CAR, V403
  • [9] INTERACTIVE DISPLAY AND ANALYSIS OF 3-D MEDICAL IMAGES
    ROBB, RA
    BARILLOT, C
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1989, 8 (03) : 217 - 226
  • [10] SCHMITZ HJ, 1989, P CAR, V390