QUANTITATIVE-DETERMINATION OF STABILIZER IN A SINGLE-BASE PROPELLANT BY CHEMOMETRIC ANALYSIS OF FOURIER-TRANSFORM INFRARED-SPECTRA

被引:15
作者
LINDBLOM, T
CHRISTY, AA
LIBNAU, FO
机构
[1] UNIV BERGEN,DEPT CHEM,N-5007 BERGEN,NORWAY
[2] CELSIUS MAT TEKN,S-69151 KARLSKOGA,SWEDEN
关键词
HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY; DATA PROCESSING; CALIBRATION; STABILIZERS; MULTIVARIATE ANALYSIS; PROPELLANTS; PARTIAL LEAST SQUARES; FOURIER TRANSFORM;
D O I
10.1016/0169-7439(95)00025-6
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The main constituent in a propellant is nitrocellulose, which by nature is unstable, and consequently it has to be stabilised with, e.g., diphenylamine. In order to determine the remaining shelflife of the propellant, the amount of stabiliser is determined. The method mostly used for this purpose, high-performance liquid chromatography (HPLC), is however complex and time consuming. Partial least squares calibration of the infrared spectroscopic profiles of the stabiliser and its derivatives in the propellant against their respective quantities (determined by HPLC) was tested to find out whether the quantitative determination of the above was possible. The initial results show that the cross-validated calibration model yields quantitative determination of the stabiliser and its derivatives within an error limit of 10% in predicted values. The correlation between the measured and predicted values was better than 0.94 for the stabiliser and its three first derivatives.
引用
收藏
页码:243 / 254
页数:12
相关论文
共 14 条
[1]  
BERGENS A, 1992, P S CHEM PROBL CONN, V9, P161
[2]   INTERPRETATION OF CHEMICAL STRUCTURAL-CHANGES BY TARGET-PROJECTION ANALYSIS OF INFRARED PROFILES [J].
CHRISTY, AA ;
KVALHEIM, OM ;
LIBNAU, FO ;
AKSNES, G ;
TOFT, J .
VIBRATIONAL SPECTROSCOPY, 1993, 6 (01) :1-14
[3]  
CURTIS J, 1990, PROPELLANTS EXPLOSIV, V15, P332
[4]  
Curtis N. J., 1987, PROPELL EXPLOS PYROT, V12, P158, DOI [10.1002/prep.19870120505, DOI 10.1002/PREP.19870120505]
[5]   A COMPARISON OF THE HEURISTIC EVOLVING LATENT PROJECTIONS AND EVOLVING FACTOR-ANALYSIS METHODS FOR PEAK PURITY CONTROL IN LIQUID-CHROMATOGRAPHY WITH PHOTODIODE ARRAY DETECTION [J].
KELLER, HR ;
MASSART, DL ;
LIANG, YZ ;
KVALHEIM, OM .
ANALYTICA CHIMICA ACTA, 1992, 267 (01) :63-71
[6]   HEURISTIC EVOLVING LATENT PROJECTIONS - RESOLVING 2-WAY MULTICOMPONENT DATA .1. SELECTIVITY, LATENT-PROJECTIVE GRAPH, DATASCOPE, LOCAL RANK, AND UNIQUE RESOLUTION [J].
KVALHEIM, OM ;
LIANG, YZ .
ANALYTICAL CHEMISTRY, 1992, 64 (08) :936-946
[7]   HEURISTIC EVOLVING LATENT PROJECTIONS - RESOLVING 2-WAY MULTICOMPONENT DATA .2. DETECTION AND RESOLUTION OF MINOR CONSTITUENTS [J].
LIANG, YZ ;
KVALHEIM, OM ;
KELLER, HR ;
MASSART, DL ;
KIECHLE, P ;
ERNI, F .
ANALYTICAL CHEMISTRY, 1992, 64 (08) :946-953
[8]  
LINDBLOM T, 1988, P S CHEM PROBL CONN, V8, P75
[9]  
LINDBLOM T, 1986, P S CHEM PROBL CONN, V7, P247
[10]  
LINDBLOM T, 1992, P S CHEM PROBL CONN, V9, P205