ELECTRICAL-STIMULATION AND MULTICHANNEL EMG RECORDING FOR IDENTIFICATION OF FUNCTIONAL NEURAL TISSUE DURING CAUDA-EQUINA SURGERY

被引:45
作者
LEGATT, AD
SCHROEDER, CE
GILL, B
GOODRICH, JT
机构
[1] YESHIVA UNIV ALBERT EINSTEIN COLL MED, DEPT NEUROL, BRONX, NY 10461 USA
[2] YESHIVA UNIV ALBERT EINSTEIN COLL MED, DEPT NEUROSCI, BRONX, NY 10461 USA
[3] YESHIVA UNIV ALBERT EINSTEIN COLL MED, DEPT UROL, BRONX, NY 10461 USA
[4] YESHIVA UNIV ALBERT EINSTEIN COLL MED, DEPT NEUROSURG, BRONX, NY 10461 USA
关键词
CAUDA EQUINA SURGERY; ELECTRIC STIMULATION; ELECTROMYOGRAPHY; EVOKED POTENTIALS; SOMATOSENSORY; INTRAOPERATIVE NEUROPHYSIOLOGIC MONITORING; TETHERED SPINAL CORD;
D O I
10.1007/BF00262842
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Electrical stimulation of structures within the surgical field was used to identify functional neural elements during 25 cauda equina operations. EMG responses from anterior thigh, posterior thigh, and anal sphincter muscles were recorded simultaneously using a multichannel signal averager. During nine operations, stimulation of a presumed filum terminale or other tissue produced clear EMG responses, prompting modification of surgical procedures. In one patient, this resulted in preservation of a flattened spinal cord which resembled a band of scar tissue. Some EMG responses were restricted to a single muscle group; these neural structures would probably not have been identified if only a single-channel EMG recording was used. Visual examination alone was not adequate for identifying functional neural elements, or for determining whether atretic-appearing nerve roots were functional. Electrical stimulation with multichannel EMG recording facilitates the preservation of functional neural elements and the optimization of surgical results in cauda equina surgery.
引用
收藏
页码:185 / 189
页数:5
相关论文
共 18 条
[1]   THE NEUROLOGIC DEFICIT ASSOCIATED WITH LIPOMAS OF THE CAUDA EQUINA [J].
BASSETT, RC .
ANNALS OF SURGERY, 1950, 131 (01) :109-116
[2]   INTRAOPERATIVE MONITORING OF FACIAL MUSCLE EVOKED-RESPONSES OBTAINED BY INTRACRANIAL STIMULATION OF THE FACIAL-NERVE - MORE ACCURATE TECHNIQUE FOR FACIAL-NERVE DISSECTION [J].
DELGADO, TE ;
BUCHHEIT, WA ;
ROSENHOLTZ, HR ;
CHRISSIAN, S .
NEUROSURGERY, 1979, 4 (05) :418-421
[3]   USE OF SOMATOSENSORY EVOKED-POTENTIALS IN INFANTS AND CHILDREN [J].
GILMORE, R .
NEUROLOGIC CLINICS, 1988, 6 (04) :839-859
[4]   IMPROVED PRESERVATION OF FACIAL-NERVE FUNCTION WITH USE OF ELECTRICAL MONITORING DURING REMOVAL OF ACOUSTIC NEUROMAS [J].
HARNER, SG ;
DAUBE, JR ;
EBERSOLD, MJ ;
BEATTY, CW .
MAYO CLINIC PROCEEDINGS, 1987, 62 (02) :92-102
[5]   RECTAL SPHINCTER PRESSURE MONITORING DEVICE [J].
HELLBUSCH, LC ;
NIHSEN, BJ .
NEUROSURGERY, 1989, 24 (05) :775-776
[6]   ANORECTAL PRESSURE MONITORING DURING SURGERY ON SACRAL LIPOMENINGOCELE - CASE-REPORT [J].
IKEDA, K ;
KUBOTA, T ;
KASHIHARA, K ;
YAMAMOTO, S .
JOURNAL OF NEUROSURGERY, 1986, 64 (01) :155-156
[7]   USE OF ANAL-SPHINCTER ELECTROMYOGRAPHY DURING OPERATIONS ON THE CONUS MEDULLARIS AND SACRAL NERVE ROOTS [J].
JAMES, HE ;
MULCAHY, JJ ;
WALSH, JW ;
KAPLAN, GW .
NEUROSURGERY, 1979, 4 (06) :521-523
[8]  
KIMURA J, 1983, ELECTRODIAGNOSIS DIS
[9]  
LEGATT AD, 1990, CLIN ANESTHESIA NEUR, P63
[10]  
LINDSAY KW, 1980, SURG NEUROL, V14, P49