EFFECTS OF RECTAL EXAMINATION, PROSTATIC MASSAGE, ULTRASONOGRAPHY AND NEEDLE-BIOPSY ON SERUM PROSTATE SPECIFIC ANTIGEN LEVELS

被引:143
作者
YUAN, JJJ
COPLEN, DE
PETROS, JA
FIGENSHAU, RS
RATLIFF, TL
SMITH, DS
CATALONA, WJ
机构
[1] WASHINGTON UNIV,SCH MED,DIV BIOSTAT,ST LOUIS,MO 63110
[2] WASHINGTON UNIV,SCH MED,DIV UROL SURG,ST LOUIS,MO 63110
关键词
PROSTATE; MASSAGE; ULTRASONIC DIAGNOSIS; BIOPSY; NEEDLE; ANTIGENS; DIFFERENTIATION;
D O I
10.1016/S0022-5347(17)37392-5
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Measurement of serum prostate specific antigen (PSA) is commonly used to evaluate the prostate gland in a variety of clinical settings. We examined the effects of prostatic manipulations, including digital rectal examination, prostate massage, transrectal ultrasonography and transrectal needle biopsy, on serum PSA levels in 199 men. We detected no clinically significant difference between serum PSA levels obtained immediately before and at 5 or 90 minutes after rectal examination in 43 men. We observed falsely increased PSA levels (to greater than 4 ng./ml., Tandem-R) in 1 of 17 men (6%) following prostatic massage and in 3 of 27 men (11%) following ultrasonography. Transrectal needle biopsy caused an immediate increase in serum PSA in 92 of 100 men. In 29 of these 92 men (32%) when followed weekly serum PSA levels did not return to baseline as expected according to the published serum PSA half-life of 2 to 3 days. Biopsies taking 3 or fewer cores (7 patients) resulted in a smaller increase in serum PSA (mean 1.63 +/- 1.12 times the baseline level versus 6.24 +/- 1.10 times baseline, p < 0.03) and a proportionally shorter duration of PSA elevation (mean 1.43 +/- 0.48 weeks versus 2.13 +/- 0.14 weeks, p = 0.20) than those taking 4 or more cores (93 patients). Prostate size and the presence of cancer had no influence on the duration of PSA elevation following biopsy. We conclude that digital rectal examination, prostatic massage and ultrasonography have minimal effects on serum PSA levels in most patients. However, prostatic needle biopsy usually causes marked elevations of serum PSA levels with a persistent PSA leak into the blood stream lasting longer than expected from the serum half-life of PSA in approximately 25% of the patients.
引用
收藏
页码:810 / 814
页数:5
相关论文
共 18 条
[1]  
BRAWER MK, 1988, ARCH PATHOL LAB MED, V112, P1110
[2]  
CARLTON CE, 1986, CAMPBELLS UROLOGY, P276
[3]   MEASUREMENT OF PROSTATE-SPECIFIC ANTIGEN IN SERUM AS A SCREENING-TEST FOR PROSTATE-CANCER [J].
CATALONA, WJ ;
SMITH, DS ;
RATLIFF, TL ;
DODDS, KM ;
COPLEN, DE ;
YUAN, JJJ ;
PETROS, JA ;
ANDRIOLE, GL .
NEW ENGLAND JOURNAL OF MEDICINE, 1991, 324 (17) :1156-1161
[4]   SERUM PROSTATE-SPECIFIC ANTIGEN - HOURLY CHANGE 24 HOURS COMPARED WITH PROSTATIC ACID-PHOSPHATASE [J].
ELSHIRBINY, AMF ;
NILSON, T ;
PAWAR, HN .
UROLOGY, 1990, 35 (01) :88-92
[5]   CLINICAL USE OF PROSTATE SPECIFIC ANTIGEN IN PATIENTS WITH PROSTATE-CANCER [J].
HUDSON, MA ;
BAHNSON, RR ;
CATALONA, WJ .
JOURNAL OF UROLOGY, 1989, 142 (04) :1011-1017
[6]  
HUGHES HR, 1987, ANN CLIN BIOCH S1, V24, P206
[7]  
LANGE PH, 1989, J UROLOGY, V141, P873
[9]   PROSTATE SPECIFIC ANTIGEN IN THE PREOPERATIVE AND POSTOPERATIVE EVALUATION OF LOCALIZED PROSTATIC-CANCER TREATED WITH RADICAL PROSTATECTOMY [J].
OESTERLING, JE ;
CHAN, DW ;
EPSTEIN, JI ;
KIMBALL, AW ;
BRUZEK, DJ ;
ROCK, RC ;
BRENDLER, CB ;
WALSH, PC .
JOURNAL OF UROLOGY, 1988, 139 (04) :766-772
[10]   PROSTATE SPECIFIC ANTIGEN IN THE STAGING OF LOCALIZED PROSTATE-CANCER - INFLUENCE OF TUMOR DIFFERENTIATION, TUMOR VOLUME AND BENIGN HYPERPLASIA [J].
PARTIN, AW ;
CARTER, HB ;
CHAN, DW ;
EPSTEIN, JI ;
OESTERLING, JE ;
ROCK, RC ;
WEBER, JP ;
WALSH, PC .
JOURNAL OF UROLOGY, 1990, 143 (04) :747-752