CARDIAC-RHYTHM PRECIPITATING AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR DISCHARGE IN OUTPATIENTS AS DETECTED FROM TRANSTELEPHONIC ELECTROCARDIOGRAPHIC RECORDINGS

被引:20
作者
STEINBERG, JS [1 ]
SUGALSKI, JS [1 ]
机构
[1] MEDTRON CARDIOCARE INC,FOREST HILLS,NY
关键词
D O I
10.1016/0002-9149(91)90109-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The automatic implantable cardioverter-defibrillator (AICD) has become a mainstay in the nonpharmacologic management of sustained ventricular tachyarrhythmias.1 One of the most significant management problems for the AICD population is that of AICD discharge for cardiac rhythms other than sustained ventricular tachyarrhythmias, the rhythms that the AICD was designed to sense and terminate.2-5 This type of AICD discharge has been termed "inappropriate," "spurious," or "false positive," can be due to a variety of cardiac rhythms, and, if recurrent, may be associated with deleterious medical or psychological consequences.1 Although the problem clearly exists, the occurrence of inappropriate AICD discharges is difficult to define in clinical practice because the current AICD system has no internal memory or telemetry functions to document the rhythms that precipitated the AICD discharge. There is little published information that documents the cause of AICD discharges in an outpatient population. The objective of this study was to survey the records of all AICD outpatients enrolled in a transtelephonic electrocardiogram monitoring service, and to review the records for (1) the cardiac rhythms responsible for the AICD discharges, and (2) the patients' symptoms preceding the AICD discharge. © 1991.
引用
收藏
页码:95 / 97
页数:3
相关论文
共 6 条
[1]   THE USE OF BEEP-O-GRAMS IN THE ASSESSMENT OF AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR SENSING FUNCTION [J].
BALLAS, SL ;
RASHIDI, R ;
MCALISTER, H ;
CORBELLI, R ;
MCCOWAN, R ;
WILKOFF, BL ;
CASTLE, LW ;
MORANT, VA ;
SIMMONS, TW ;
MALONEY, JD .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (11) :1737-1745
[2]   THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - EVALUATING SUSPECTED INAPPROPRIATE SHOCKS [J].
CHAPMAN, PD ;
TROUP, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (05) :1075-1078
[3]  
ECHT DS, 1985, CLIN PROGR, V3, P14
[4]   ACTUARIAL INCIDENCE AND PATTERN OF OCCURRENCE OF SHOCKS FOLLOWING IMPLANTATION OF THE AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR [J].
FOGOROS, RN ;
ELSON, JJ ;
BONNET, CA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (09) :1465-1473
[5]   AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - PATIENT SURVIVAL, BATTERY LONGEVITY AND SHOCK DELIVERY ANALYSIS [J].
GABRY, MD ;
BRODMAN, R ;
JOHNSTON, D ;
FRAME, R ;
KIM, SG ;
WASPE, LE ;
FISHER, JD ;
FURMAN, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (06) :1349-1356
[6]   OUT-OF-HOSPITAL AUTOMATIC CARDIOVERSION OF VENTRICULAR-TACHYCARDIA [J].
RUFFY, R ;
SMITH, P ;
LASETER, M ;
LAL, R ;
KIM, SS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (02) :482-485