ULTRASONIC MYOCARDIAL INTEGRATED BACKSCATTER AND MYOCARDIAL WALL THICKNESS IN ANIMAL-EXPERIMENTS

被引:31
作者
RIJSTERBORGH, H [1 ]
MASTIK, F [1 ]
LANCEE, CT [1 ]
VANDERSTEEN, AFW [1 ]
SASSEN, LMA [1 ]
VERDOUW, PD [1 ]
ROELANDT, J [1 ]
BOM, N [1 ]
机构
[1] INTERUNIV CARDIOL INST NETHERLANDS,ROTTERDAM,NETHERLANDS
关键词
End diastole; End systole; Integrated backscatter; Myocardium; Ultrasound; Wall thickness;
D O I
10.1016/0301-5629(90)90083-O
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The purpose of this study was to distinguish between normal and ischemic myocardium using ultrasonic integrated backscatter (IB) measurements and to relate IB with myocardial wall thickness. IB was measured in 9 open-chested Yorkshire pigs (24-30 kg) before, after 30 minutes of partial occlusion of the proximal left anterior descending coronary artery (LADCA), and after 60 minutes of subsequent reperfusion. The ultrasound transducer (4 MHz) was sutured onto the epicardial surface perfused by the LADCA. IB measurements were made with a repetition rate of 50 times per heart rate simultaneously with a left ventricular pressure signal. Myocardial wall thickness was measured off-line. The measurements of integrated backscatter, left ventricular pressure and wall thickness were based on mean values of ten subsequent cardiac cycles. End-systolic IB measurements were 5.3 dB higher during occlusion as compared to the reference measurements (7.1 ± 3.2 dB versus 1.8 ± 2.6 dB; p = 0.002). No statistically significant differences were found in end-systolic IB measurements. End-systolic wall thickness was 5 mm smaller during occlusion as compared to the reference measurements (7.2 ± 1.4 mm versus 12.2 ± 1.2 mm; p < 0.001). Simple linear regression analysis showed a statistically significant inverse relationship between IB measurements and wall thickness in 21 out of the 23 sequences in which wall thickness could be measured. End-systolic IB measurements are favourable to distinguish acute ischemic myocardium from normal myocardium. There is a distinct inverse relationship between IB and myocardial wall thickness. © 1990.
引用
收藏
页码:29 / 36
页数:8
相关论文
共 14 条
[1]  
Bloomfield P, 1976, FOURIER ANAL TIME SE, P80
[2]   EFFECTS OF CORONARY-ARTERY OCCLUSION AND REPERFUSION ON CARDIAC CYCLE-DEPENDENT VARIATION OF MYOCARDIAL ULTRASONIC BACKSCATTER [J].
GLUECK, RM ;
MOTTLEY, JG ;
MILLER, JG ;
SOBEL, BE ;
PEREZ, JE .
CIRCULATION RESEARCH, 1985, 56 (05) :683-689
[3]   PHASE-INSENSITIVE DETECTION FOR MEASUREMENT OF BACKSCATTERED ULTRASOUND [J].
JOHNSTON, PH ;
MILLER, JG .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1986, 33 (06) :713-721
[4]   MYOCARDIAL BACKSCATTER ANALYSIS IN ANIMAL-EXPERIMENTS [J].
LANCEE, CT ;
MASTIK, F ;
RIJSTERBORGH, H ;
BOM, N .
ULTRASONICS, 1988, 26 (03) :155-163
[5]   ULTRASONIC CHARACTERIZATION OF MYOCARDIUM [J].
MILLER, JG ;
PEREZ, JE ;
SOBEL, BE .
PROGRESS IN CARDIOVASCULAR DISEASES, 1985, 28 (02) :85-110
[6]   REGIONAL DIFFERENCES IN THE CYCLIC VARIATION OF MYOCARDIAL BACKSCATTER THAT PARALLEL REGIONAL DIFFERENCES IN CONTRACTILE PERFORMANCE [J].
MOTTLEY, JG ;
GLUECK, RM ;
PEREZ, JE ;
SOBEL, BE ;
MILLER, JG .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1984, 76 (06) :1617-1623
[7]  
ODONNELL M, 1979, P IEEE ULTRASONICS S, V79, P175
[8]   BISOPROLOL IMPROVES PERFUSION OF ISCHEMIC MYOCARDIUM IN ANESTHETIZED PIGS [J].
SASSEN, LMA ;
DENBOER, MO ;
RENSEN, RJ ;
SAXENA, PR ;
VERDOUW, PD .
BRITISH JOURNAL OF PHARMACOLOGY, 1988, 95 (02) :361-370
[9]   ULTRASOUND TISSUE CHARACTERIZATION - CAN THE STATE OF THE MYOCARDIUM BE ASSESSED DIRECTLY YET NONINVASIVELY [J].
SKORTON, DJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (01) :92-94
[10]   ULTRASOUND INTEGRATED BACKSCATTER TISSUE CHARACTERIZATION OF REMOTE MYOCARDIAL-INFARCTION IN HUMAN-SUBJECTS [J].
VERED, Z ;
MOHR, GA ;
BARZILAI, B ;
GESSLER, CJ ;
WICKLINE, SA ;
WEAR, KA ;
SHOUP, TA ;
WEISS, AN ;
SOBEL, BE ;
MILLER, JG ;
PEREZ, JE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (01) :84-91