DETECTION OF BROMOBENZENE-INDUCED HEPATOCELLULAR NECROSIS USING MAGNETIC-RESONANCE MICROSCOPY

被引:7
作者
ZHOU, XH
MARONPOT, RR
HEDLUND, LW
COFER, GP
JOHNSON, GA
机构
[1] DUKE UNIV,MED CTR,DEPT RADIOL,CTR VIVO MICROSCOPY,DURHAM,NC 27710
[2] NATL INST ENVIRONM HLTH SCI,RES TRIANGLE PK,NC
关键词
MR MICROSCOPY; IN VIVO HISTOLOGY; HEPATOCELLULAR NECROSIS;
D O I
10.1002/mrm.1910340610
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors used magnetic resonance (MR) microscopy to assess hepatic tissue damage induced by bromobenzene both in living rats and in fixed rat liver tissues, Experiments were conducted at 7 Tesla on three groups of Fisher rats treated with bromobenzene at a single dose of 68, 135, and 269 mg/kg, respectively, Optical microscopy of hematoxylin and eosin stained sections showed liver damage only at the highest dose, whereas with MR microscopy, tissue alterations were detected at all three doses both in vivo and ex vivo, The contrast mechanism of the superior sensitivity of MR microscopy is believed to be related to the changes in local diffusion coefficients that accompany cellular degeneration and death, although other contrast mechanisms may also be involved, The superior sensitivity of MR microscopy, as demonstrated in this study, has many implications for potential use of MR techniques to perform in vivo histology.
引用
收藏
页码:853 / 857
页数:5
相关论文
共 18 条
[1]  
Plaa G.L., Toxic response of the liver, Toxicology: The Basic Science of Poisons, (1991)
[2]  
Jollow D.J., Mitchell J.R., Zampaglione N., Gillette J.R., Bromobenzene‐induced liver necrosis: protective role of glutathione and evidence for 3, 4‐bromobenzene oxide as the hepatotoxic metabolite, Pharmacology, 11, pp. 151-169, (1974)
[3]  
Lau S.S., Monks T.J., The contribution of bromobenzene to our current understanding of chemically‐induced toxicities, Life Sci., 42, pp. 1259-1269, (1988)
[4]  
Zhou X., Maronpot R.R., Cofer G.P., Hedlund L.W., Johnson G.A., Studies on bromobenzene‐induced hepatotoxicity using in vivo MR microscopy with surgically implanted RF coils, Magn. Reson. Med., 31, pp. 619-627, (1994)
[5]  
Zhou X., Cofer G.P., Mills G.I., Johnson G.A., (1992)
[6]  
Schnall M.D., Barlow C., Subramanian V.H., Leigh J.S., Wireless implanted magnetic resonance probes for in vivo NMR, J. Magn. Reson., 68, pp. 161-167, (1986)
[7]  
Hollett M.D., Cofer G.P., Johnson G.A., In situ magnetic resonance microscopy, Invest. Radial., 22, pp. 965-968, (1987)
[8]  
Farmer T.H.R., Johnson G.A., Cofer G.P., Maronpot R.R., Dixon D., Hedlund L.W., Implanted coil MR microscopy of renal pathology, Magn. Reson. Med., 10, pp. 310-323, (1989)
[9]  
Hanson M.B., Cofer G.P., Black R.D., Johnson G.A., A probe for specimen magnetic resonance microscopy, Invest. Radial., 27, pp. 157-164, (1992)
[10]  
Hedlund L.W., Johnson G.A., Mills G.I., Magnetic resonance microscopy of the rat thorax and abdomen, Invest. Radial., 21, (1986)